To download the full installation manual and register your product, please visit:
www.DSC.com/m/29009812 or scan the QR code to the right.
Use this guide in conjunction with the PowerSeries Neo Reference Manual available online from the DSC website.
Quick Setup
1
Plan
Plan the installation including all alarm detection devices,
zone expanders, keypads and other required modules.
2
Mount
Decide on a location for the alarm panel and secure it to the
wall using suitable mounting hardware.
3
Wire
Complete all wiring including modules, zones, bells/sirens,
telephone line connections and ground connections. Record
module serial numbers on page 16.
4
Power
Connect the battery and power up the system. The battery
must be connected.
5
Enroll
Hardwired: Wire the keypad to the Corbus, power up the
First
alarm panel then press any button on the keypad. Wireless:
Keypad
Wire the HSM2Host to the Corbus, then power up the alarm
panel and a wireless keypad. Press any button on the keypad to
enroll it. The HSM2Host is then enrolled on the alarm panel.
Alternately, enroll an RF keypad.
6
Enroll
[*][8][Installer Code][902] subsection [000]. Press [*] to
begin auto-enrollment. Module slots are automatically
modules
assigned. Use scroll keys to view slots. Change slot by typing a
2-digit number.
7
Enroll
[*][8][Installer Code][804] subsection [000]. Note: An
wireless
HSM2HOST or RF keypad must be enrolled first.
devices
8
Program
Basic programming: [*][8][installer code] [001]/[002]> Zone
Type/Zone Attribute [005]>[001] Partition 1 Timers: – Entry
Delay 1 – Entry Delay 2 – Exit Delay [301]>[001] Phone #1
[310]>[000] System Account Code.
9
Test
Test the panel completely to ensure that all features and
functions operate as programmed. – [901] Walk Test – [904]
[000] Wireless Placement Test.
Compatible Devices
Throughout this document, x in the model number represents the operating
frequency of the device as follows: 9 (912-919 MHz), 8 (868MHz), 4
(433MHz).
Note: Only models operating in the band 912-919 MHz are UL/ULC listed
where indicated. Only UL approved devices are to be used with UL/ULC
listed systems.
Table 1-1 Compatible Devices
Modules
Wireless keypads
HS2LCDWFx
HS2LCDWFPx
Hardwired keypads with 2-way
HS2LCDRFx
HS2LCDRFPx
wireless integration module
Hardwired keypads
HS2LCD
HS2LCDP
HS2ICN
Touchscreen Keypad
HS2TCHP
Note: For ULC-s559 Listed applications the HS2TCHP touch screen keypad is for supplementary use
only.
2-way wireless integration module
HSM2HOSTx
8-zone expander
HSM2108
8-output expander
HSM2208
Power supply
HSM2300
4 high current output expander
HSM2204
Alternate communicator
3G2080E
3G2080RE
WARNING: This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
PowerSeries Neo Alarm Control Installation Guide
UL
UL
HS2LCDWFPVx
UL
UL
UL
HS2ICNRFx
UL
UL
HS2ICNRFPx
UL
UL
HS2ICNP
UL
UL
HS2LED
UL
UL
UL
UL
UL
UL
UL
UL
TL2803GE
UL
UL
TL2803GRE
TL280E
TL280RE
LE2080(R)
TL280LE(R)
Hardwired Devices
2-wire smoke detectors
FSA-210x
FSA-210xT
y= A, B, or C
FSA-210xS
A: ULC listed models
FSA-210xST
B: UL listed models
FSA-210xLST
C: European and Australian models
4-wire smoke detectors
FSA-410x
FSA-410xT
FSA-410xS
y= A, B, or C
FSA-410xST
A: ULC listed models
FSA-410xLST
B: UL listed models
C: European and Australian models
CO detectors
CO-12/24
12-24SIR
FW-CO12
Wireless Devices
PG smoke detectors
PG smoke and heat detector
PG CO detector
PG PIR motion detectors
PG PIR + camera motion detector
PG curtain motion detector
PG dual tech motion detector
PG mirror motion detector
PG outdoor motion detector
PG glass break detector
PG shock detector
PG flood detector
PG temperature detector (indoor use)
Outdoor temperature probe (requires PGx905)
PG flat PIR
PG recessed contact
PG ceiling mount detector with Smart Presence – Short Range
PG ceiling mount detector with Smart Presence – Long Range
PG outdoor contact
PG outdoor curtain PIR
PG keys
PG panic key
PG 2-button key
PG sirens
PG repeater
PG door/window contacts
PG door/window contact w/ AUX
Central Station Receivers
SG-System I, II, III, IV, 5
Enclosures
PC5003C, PC4050CR (ULC Fire Monitoring), PC4050CAR (UL Commercial Burg), CMC-1(UL
Commercial Burg), PC4051C. Other enclosures are available to suit a variety of system configurations.
UL
TL8803G
UL
TL880LT
TL880LE
UL
PCL-422
UL
UL
FSA-210xR
UL
UL
FSA-210xRT
UL
UL
FSA-210xRS
UL
UL
FSA-210xRST
UL
UL
FSA-210xLRST
UL
UL
FSA-410xR
UL
UL
FSA-410xRT
UL
UL
FSA-410xRS
UL
UL
FSA-410xRST
UL
UL
FSA-410xLRST
UL
UL
FW-CO1224
UL
UL
CO1224
UL
UL
PGx926
UL
PGx936, PGx916
UL
PGx933, PGx913
UL
PGx904(P)
UL
PGx934(P)
UL
PGx924
PGx984(P)
UL
PGx974(P)
UL
PGx994
UL
PGx912, PGx922
UL
PGx935
UL
PGx985
UL
PGx905
PGTEMP-PROBE
UL
PGx914
UL
PGx307
UL
PGx862
UL
PGx872
UL
PGx312
PGx902
UL
PGx939
UL
PGx929
UL
PGx938
UL
PGx949
UL
PGx901
UL
PGx911
UL
PGx920
UL
PGx303, PGx975
UL
PGx945