Ashley AW2520E-P Owner’s Instruction And Operation Manual

Ashley AW2520E-P Owner’s Instruction And Operation Manual

Advertisement

Owner's Instruction and Operation Manual
Model Numbers:
AW2520E-P • AW2520E-BP
AW2520E-L • AW2520E-BL
Report Number: F19-487
Tested Per EPA Methods ALT-125, ASTM
E2515, ASTM E3053 and CSA B415
Certified to UL 1482-2011 (R2015) and
ULC-S627-00-REV1
Mobile home approved (USA ONLY)
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
853582H-1805K
www.P65warnings.ca.gov
Ph. 800-750-2723

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AW2520E-P and is the answer not in the manual?

Questions and answers

Troy Bentley
April 12, 2025

Fire Box dim.

Charles Douglas Hogg
April 14, 2025

Where is the fresh air intake and is there a part # with fan included

1 comments:
Mr. Anderson
April 15, 2025

The Ashley AW2520E-P wood stove does not come with a fan (blower) or an outside air kit included. The fresh air intake location is not specified, but installation instructions for the air intake kit are supplied separately, and the part number must be specified when ordering through a heater dealer.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Ashley AW2520E-P

  • Page 1 Owner’s Instruction and Operation Manual Model Numbers: AW2520E-P • AW2520E-BP AW2520E-L • AW2520E-BL Report Number: F19-487 Tested Per EPA Methods ALT-125, ASTM E2515, ASTM E3053 and CSA B415 Certified to UL 1482-2011 (R2015) and ULC-S627-00-REV1 Mobile home approved (USA ONLY) * All Pictures In This Manual Are For Illustrative Purposes Only.
  • Page 2 INTRODUCTION This manual describes the installation and operation of the Ashley, AW2520E wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 20,374 to 60,065 Btu/hr (*0.88 g/hr and an efficiency of 73%).
  • Page 3: Installation Checklist

    INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Tools And Materials

    ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 TOOLS AND MATERIALS ASH PAN ASSEMBLY You will need a drill with a 1/8” bit to install sheet metal Remove ash pan from firebox. Under the firebox, screws into connector pipe. A 5/16” socket/wrench there are two brackets;...
  • Page 5: Installation

    ASSEMBLY INSTRUCTIONS FIREBRICK CONFIGURATION AIR DEFLECTOR ASSEMBLY Replace the Firebrick as shown in the illustration. Use the provided screws to attach the air deflector to the rear of the unit. INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
  • Page 6: Floor Protector

    INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 FLOOR PROTECTOR an attic or roof space, closet or similar concealed space, a floor, or a ceiling. This heater must have a non-combustible floor protector with an R-Value of at least 1.4 installed •...
  • Page 7: Chimney Connector (Stove Pipe)

    INSTALLATION 2. Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smell, do not operate properly, suffer smoke roll-out when opened, or back-drafts occur whether or not there is combustion present. 3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
  • Page 8: Importance Of Proper Draft

    INSTALLATION CHIMNEY assembled to promote the male section (crimped end) of the pipe to be faced down. Attach each section to another with three metal screws spaced an equal distance apart. The pipe must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot, with the upper end of the section toward the chimney.
  • Page 9: Factory Built Chimney

    INSTALLATION 5. Using a fire screen at the extremity of the Concrete Cap chimney requires regular inspection to ensure Fireclay Flue Liner With that it is not obstructed thus blocking the draft, Airspace 1” Clearance with Firestop and it should be cleaned when used regularly. FACTORY BUILT CHIMNEY Rafter Flashing...
  • Page 10 INSTALLATION METHOD B - 9” (229 mm) Clearance to Combustible Wall Member: Using a 6” (153 mm) inside diameter, listed, factory-built Solid-Pak chimney section with insulation of 1” (26 mm) or more, build a wall pass- through with a minimum 9” (229 mm) air space between the outer wall of the chimney length and wall combustibles.
  • Page 11: Wood Stove Utilization

    OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED OPERATING SAFETY PRECAUTIONS CAUTIONS: HOUSE FIRE HAZARDS • NEVER OVERFIRE THIS APPLIANCE BY • DO STORE WOOD FLOOR BUILDING EXCESSIVELY HOT FIRES AS A PROTECTOR, UNDERNEATH STOVEPIPE(S) HOUSE/BUILDING FIRE MAY RESULT. YOU OR ANYWHERE WITHIN CLEARANCES TO ARE OVERFIRING THE APPLIANCE IF IT COMBUSTIBLE SURFACES SPECIFIED FOR...
  • Page 12: Testing Your Wood

    OPERATION INSTRUCTIONS wax, and similar substances to start a fire in an temperature never rises higher than 475 °F (246 affected wood heater. °C) on a magnetic thermometer for installation on single wall stove pipes or 900 °F (482 °C) on a probe Burning these materials may result in the release thermometer for installation on double wall stove of toxic fumes or render the heater ineffective...
  • Page 13: Fueling Instructions

    OPERATION INSTRUCTIONS fire is established a lower burn rate may be a better option for efficient heating. A lower burn rate slows the flow of usable heat out of the home through the chimney, and it also consumes less wood. NOTICE INITIAL BURNS TO CURE PAINT 7 lb BECAUSE OF HIGH OPERATING TEMPERATURES,...
  • Page 14: Air Tubes

    OPERATION INSTRUCTIONS VISIBLE SMOKE coal bed, load the unit with 32 lbs of cordwood and close the door immediately. Leave the air control The amount of visible smoke being produced can be fully open (in the “HI” position) for 4.5 minutes then an effective method of determining how efficiently close halfway.
  • Page 15: Chimney Maintenance

    CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED • Leave the air control fully open for about 5 min. CAUTION: every time you reload the stove to bring it back DO NOT OVERFIRE APPLIANCE. YOU ARE to proper operating temperatures. The secondary OVERFIRING IF ANY PART OF THE APPLIANCE combustion can only take place if the firebox is GLOWS RED.
  • Page 16: Glass Care

    CHIMNEY MAINTENANCE SMOKE & CO MONITORS replacing it. When replacing the glass, you should change the glass gasket to make sure you keep it Burning wood naturally produces smoke and sealed. carbon monoxide(CO) emissions. CO is a poisonous gas when exposed to elevated concentrations for •...
  • Page 17: Repair Parts

    REPAIR PARTS Part # Description 40292A 6” Flue Collar 88042 1/4” Rope Gasket 25845 Air Deflector 891492 Blower Assembly (B36) 26060 Rear Shield 610926 Rear Ashpan (AW2520E-BP) 29243 Pedestal (AW2520E-BP) 29065 Pedestal Front (AW2520E-BP) Pedestal Base Weldment 610969 (AW2520E-BP) 610968 Ashpan Housing (AW2520E-BL) 40566 Cast Iron Leg...
  • Page 18 REPAIR PARTS Part # Description 88325 Kao Wool Blanket 88138 Ceramic Fiber Board 86643 Secondary Air Tube (Ø5/32) 29247 Right Brick Panel 86645 Secondary Air Tube (Ø7/32) 29248 Left Brick Panel Half Firebrick Pumice (4- 24103A 1/2 X 4-1/2) 40561 Ash Plug 891530A Firebrick (4.5 X 7.5 X 1.25)
  • Page 19: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 20 NOTES © 2021 United States Stove Company...