2. INTRODUCTION & SPECIFICATION
A totally dry heat, no condensation, no gas, no fumes and no smell. Reaches maximum heat output within seconds of being turned on. Highly polished
aluminium reflector for maximum heat efficiency. Adjusts horizontally through 25° while mounted. Three settings, controlled by pull cord, allowing unit to
be on full, half or low power. Ideal for industrial or domestic applications. Suitable for indoor and outdoor use, if weather protected (Heater is IP24 rated).
Model No
Power:
Input supply:
Dimensions (W x H x D):
Minimum / Maximum Height:
3. MOUNTING INSTALLATION
3.1
Assembly (fig.1).
3.2
Insert the welded plate end of section 9 into the base 10 and secure using washer 11 and
screw 12.
3.3
Silde section 8 onto section 9 and secure using screw 14. Slide section 5 upwards from inside
of section 7, turn lock screw 6 clockwise to secure and then slide section 7 onto section 8 and
secure using screw 14.
3.4
Insert the end of section 5 into the base of the heater (1) and secure with screw 13.
3.5
Align Clip 3 to the holes in sections 7 and 9 and secure with screw 4.
4. OPERATION
WARNING! Ensure you read, understand and apply the safety instructions in Section 1
before using the heater.
4.1
Ensure the heater is at least 1m from any object, 300m from the ceiling. The heater can be tilted
from 0° to 25°, set it to the required angle before switching the heater on.
4.2
Plug in the heater and switch it on using the pull chord on the heater head.
4.3
The heater will start on the low setting, each pull of the chord will cycle the heater onto the
medium setting, high setting and then back to off. (fig.1B)
4.4
When the heater is no longer required, switch to the off position and unplug the unit.
4.5
Make sure the heater plug is disconnected from the mains supply before any cleaning is
attempted. Also allow the heater to cool completely.
DO NOT use harsh abrasive cleaners to clean the heater.
DO NOT touch the glass elements with fingers as this may damage the tube.
4.6
Clean the exterior with a soft damp cloth with some mild detergent.
4.7
To replace any of the elements, contact your authorised Sealey dealer.
Declaration of Conformity
standards and directives.
INFRARED PATIO HEATER
Models: IFSH2003
2006/95/EC low Voltage Directive
2004/108/EC EMC Directive
93/68/EEC Marking Directive
2002/95/EC RoHS Directive
2002/96/EC WEEE Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
IFSH2003
2000W
230V 13A
485 x 170 x 250 mm
1530mm / 1850mm
We, the sole importer into the UK, declare that the product listed here is in conformity with the following
The construction file for this product is held by the Manufacturer and may be inspected, by
a national authority, upon request to Jack Sealey ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
20th April 2009