ListenTech-Note
_________________________________________________________________________________

Remote Powering the LT-84 Transmitter/Radiator Combo

OVERVIEW:
In the event an AC outlet is not located close to the LT-84 Transmitter/Radiator mounting location, it may
be necessary to remotely locate the power supply and run cable to the LT-84. There are two options
available to remotely power the LT-84. This tech note outlines the cable distances that can be achieved
with each option along with the number of Expansion Radiators (LA-141) supported. If more than two
expansion radiators will be connected to the LT-84, then an AC outlet near the LT-84 will be required.

OPTION 1: Remote Powering the LT-84 using CAT-5 cable (24 AWG)

This option requires the purchase of Listen's
This kit converts the power supply barrel connector to an RJ-45 connector so that standard CAT-5 cable
can be used between the power supply and the LT-84, as shown below. The CAT-5 cable must be 24
AWG to achieve the distances listed in the table below. This option can be used with a standalone LT-84
or an LT-84 with one LA-141 Expansion Unit. To support up to two LA-141's, proceed to option 2.
Option 1: Maximum Distance using CAT-5 Cable (24 AWG)
Maximum CAT-5 cable distance
between the power supply and LT-84
# LTN0035
Doc.
LPT-A117
remote power supply kit (MSRP $9.00).
LT-84
Standalone
30 m. (100 ft.)
Page 1 of 2
LT-84 plus (1) LA-141
Expansion Radiator
12 m. (40 ft.)
Revision: 04-25-18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LT-84 and is the answer not in the manual?

Questions and answers

Summary of Contents for Listen Technologies LT-84

  • Page 1 This kit converts the power supply barrel connector to an RJ-45 connector so that standard CAT-5 cable can be used between the power supply and the LT-84, as shown below. The CAT-5 cable must be 24 AWG to achieve the distances listed in the table below. This option can be used with a standalone LT-84 or an LT-84 with one LA-141 Expansion Unit.
  • Page 2 This option converts the power supply barrel connector to a terminal connector so that standard 14 AWG speaker wire can be used between the power supply and the LT-84 as shown below. The speaker wire must be 14 AWG to achieve the distances listed in the table. This option can be used with a standalone LT-84, an LT-84 with one LA-141 Expansion Unit or an LT-84 with two LA-141 Expansion Units.

Table of Contents