Connecting

5.2 Connecting the SIMATIC IOT2000 SG-Shield

5.2
Connecting the SIMATIC IOT2000 SG-Shield
Procedure
1
4
SIMATIC IOT2000 SG-Shield
Load cell
Load cell terminals
LEDs (Page 27)
1. Connect the SIMATIC IOT2000 SG-Shield
For 4-wire load cells, do not connect SENSE - and SENSE+.
The load cells are connected in parallel. There is no individual channel diagnostics.
2. Select in the software whether you have connected 4-wire or 6-wire load cells. See
section Setting the commissioning parameters (Page 19).
16
SENSE-
EXC-
SIGNAL-
3
SENSE+
EXC+
SIGNAL+
to the four load cells
Operating Instructions, 08/2021, A5E50985404-AA