Installation, Operation and Maintenance Guide 500 Series OUR MISSION IMPORTANT To improve health and wellness by actively restoring indoor air Save this Document AtmosAir.com to its pure, natural state where no pollution or contaminants for Future Reference & CAG-06-21-003 exist, while reducing energy use and emissions in the process. Warranty Information...
Page 2
Installation, Operation & Maintenance Guide 500 Series !IMPORTANT! READ THIS BEFORE STARTING INSTALLATION. DO NOT THROW AWAY THIS GUIDE. For safe installation you MUST: ■ Always disconnect power to the unit before handling any of the components. ■ DO NOT connect to the power before the installation is complete and personnel are aware of the imminent operation.
Installation, Operation & Maintenance Guide 500 Series 01 PRODUCT OVERVIEW Control Panel Diagram The AtmosAir 500 series, models 500EC, 500FC and 508FC, AtmosAir 500 Series Control Panel Layout: ionization generators are industrial quality units intended for installation in air conditioning systems or in custom-designed air distribution systems in commercial and industrial facilities.
Installation, Operation & Maintenance Guide 500 Series 02 INSTALLATION Mechanical Installation The AtmosAir 500 series equipment can be mounted on the 1. Carefully remove the equipment from its shipping side of a duct or air handler wall, using the integral mounting container.
2. The unit is equipped with a normally open relay that closes on ionization start-up and opens on loss of power. This relay AtmosAir 500 series systems require an average of 50 watts can initiate a local alarm or be tied into a building automation per unit.
Installation, Operation & Maintenance Guide 500 Series 03 FIELD WIRING DIAGRAM 1/4" POLYETHYLENE TUBING X 36" BLACK (HOT) WIRE TO N/O PROVIDED NORMALLY OPEN AND COM AIRFLOW SAMPLING TUBE INSERT 6" INTO AHU OR DUCT AFTER ARMORFLEX FAN, AIRFLOW INTO TUBE END. SHIELDED CABLE SILICONE IN PLACE 10' (3M) LONG...
Installation, Operation & Maintenance Guide 500 Series 04 OPERATION ■ Optional: Check performance using a high voltage probe Once the system is properly installed and all personnel are (minimum of 5000 V, Contact AtmosAir for additional minimum clear of the high voltage tubes, the system can be turned on: probe specifications) paired with a multimeter.
Installation, Operation & Maintenance Guide 500 Series 06 TROUBLESHOOTING 7. If physical inspection has not revealed the cause of In the event that the system is not functioning, follow these steps IN ORDER: failure, one may carefully observe the tubes as the ionization system is turned on to determine whether 1.
Installation, Operation & Maintenance Guide 500 Series 07 EXPLANATION OF TECHNOLOGY 07 EXPLANATION OF TECHNOLOGY 07 EXPLANATION OF TECHNOLOGY AtmosAir Solutions’ ™ mission is to bring and restore every indoor environment the same clean and pure quality air that is typically found at higher mountain elevations.
(27) months from the date of Clean Air Group’s delivery of the product, whichever occurs first, Clean Air Group shall repair or replace the product without charge to the Customer. Proof of malfunction and return of the non- working product must be presented by the Customer if submitting a warranty claim.