11 Troubleshooting

11 Troubleshooting
11.1

Resolving error codes

Fig.73
Hybrid Mode
Electrical
Timer /
Heating
Clock
Tab.28
Ex-type error codes
Code
Description
Communication error between the outdoor unit and the
control panel
Water temperature sensor T5L error
Evaporation temperature sensor T3 error
Air temperature sensor T4 error
Air suction temperature sensor Th error
Air discharge temperature sensor Tp error
70
SPC Split
Opt Mode
Enter
If an error occurs, the control panel will display a key and a code The code
is important for the correct and rapid diagnosis of the type of malfunction
and for any technical assistance that may be needed.
1. Make a note of the code displayed.
2. Switch off the appliance.
3. Switch the appliance back on.
The appliance starts up again autonomously when the reason for
the disruption has been cleared.
4. If the error code is displayed again, correct the problem by following
the instructions in the table below.
11.1.1

List of error codes

Causes and corrective actions
Check the connection between the outdoor unit and
the control panel.
Replace the control panel if necessary.
Communication fault: check the connection.
Damaged sensor: replace the sensor.
Communication fault: check the connection.
Damaged sensor: replace the sensor.
Communication fault: check the connection.
Damaged sensor: replace the sensor.
Communication fault: check the connection.
Damaged sensor: replace the sensor.
Communication fault: check the connection.
Damaged sensor: replace the sensor.