Summary of Contents for Champion Power Equipment 100110
Page 1
OWNER’S MANUAL & OPERATING INSTRUCTIONS 11500 Starting Watts / 9200 Running Watts Electric Start PORTABLE GENERATOR MODEL NUMBER 100110 12039 Smith Ave. SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 Important safety instructions USA / 1-877-338-0999 are included in this manual. REV 100110-20210202 www.championpowerequipment.com...
Page 2
AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods.
INTRODUCTION Introduction Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
100110 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death.
100110 ENGLISH SAFETY RULES WARNING DANGER Generator produces powerful voltage. Read this manual thoroughly before operating your generator. Failure to follow instructions could result DO NOT touch bare wires or receptacles. in serious injury or death. DO NOT use electrical cords that are worn, damaged or frayed.
Page 7
100110 ENGLISH SAFETY RULES DANGER WARNING Fuel and fuel vapors are highly flammable and Rapid retraction of the starter cord will pull hand and extremely explosive. arm towards the engine faster than you can let go. Fire or explosion can cause severe burns or death.
SAFETY RULES Safety Label Locations These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Champion Power Equipment’s customer service department for possible replacement. WARNING...
100110 ENGLISH CONTROLS AND FEATURES Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator Fuel Tank – 7.7 gal. (29 L) capacity fuel tank.
100110 ENGLISH CONTROLS AND FEATURES Power Panel Ignition Switch – Used to start or stop the Ground Terminal – Consult an electrician for local generator. grounding regulations. Intelligauge with Power Meter – Five mode digital 120/240 Volt AC / 50 Amp Receptacle meter for displaying running hours, total time, (NEMA 14-50R) –...
100110 ENGLISH CONTROLS AND FEATURES Parts Included Your 100110 gasoline generator ships with the following parts: Wheel Kit – 9.5 in. (24.1 cm) Wheel ....
100110 ENGLISH ASSEMBLY Install the Support Leg Your generator requires some assembly. This unit ships from our factory without oil and fuel. It must be properly 1. Attach the support leg to the generator frame with serviced with fuel and oil before operation.
100110 ENGLISH ASSEMBLY Add Engine Oil Add Engine Oil Cont’d. CAUTION NOTE Check oil often during the break-in period. Refer to the DO NOT attempt to crank or start the engine before Maintenance section for recommended service intervals. it has been properly filled with the recommended type and amount of oil.
100110 ENGLISH ASSEMBLY Add Fuel Add Fuel Cont’d. 1. Use clean, fresh, regular unleaded fuel with a NOTE minimum octane rating of 87 and an ethanol content of less than 10% by volume. Our engines work well with 10% or less ethanol 2.
100110 ENGLISH OPERATION Generator Location Grounding NEVER operate the generator inside any building, The generator system ground connects the frame to the including garages, basements, crawlspaces and sheds, ground terminals on the power panel. The system ground is enclosure or compartment, including the generator connected to the AC neutral wire.
100110 ENGLISH OPERATION Starting the Engine Cont’d. Connecting Electrical Loads Cont’d. NOTE NOTE Keep choke lever in “Choke” position for only 1 Connecting a generator to your electric utility pull of the recoil starter. After first pull, move choke company’s power lines or to another power source lever to the “Run”...
To alleviate high altitude issues other than the natural calculated in step 2. Surge wattage is the extra power loss, Champion Power Equipment can provide a burst of power needed to start some electric driven high altitude carburetor main jet. The alternative main equipment.
Champion Power Equipment recommends that you consult with a licensed, local electrician. Due to the variety of local codes, we cannot specifically advise you regarding...
100110 ENGLISH MAINTENANCE AND STORAGE Oil Cont’d. The owner/operator is responsible for all periodic maintenance. NOTE WARNING Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. Never operate a damaged or defective generator.
Contact our helpline at 1-877-338-0999 to locate the 3. Remove the spark arrester screen. nearest Champion Power Equipment certified service 4. Carefully remove the carbon deposits from the spark arrester screen with a wire brush. dealer for your generator or engine maintenance needs.
100110 ENGLISH MAINTENANCE AND STORAGE Storage Charge the Battery For a generator equipped with batteries for electric The generator should be started at least once every starting, proper battery maintenance and storage should 14 days and allowed to run for at least 20 minutes. For be followed.
Rotor Assembly, Cu, Ø204 x 158 mm, 155.191100.00 107 5.1330.018 Sheath, Wire, Ø16 x 180 mm 108 152.210003.02 Plug, End Cover 152.192300.01 Air Guide 109 100110.21.10 Wire Assembly 48.601 Engine, 459cc 110 100110.21 Control Panel Assembly 5.1900.026 Grounding Line 150 mm 1.5789.0612...
100110 ENGLISH Part Number Description Part Number Description 47.021000.00 Cover, Cylinder Head 21.061300.00 Handle, Recoil, Soft 45.020001.02 Breather Tube 1.5789.0608 Flange Bolt M6 x 8 47.020100.00 Bolt, Cylinder Head Cover 46.061100.00.2 Cover, Recoil Starter, Black 2.08.039 Drain Bolt M12 x 1.5 x 15 45.060005.00...
100110 ENGLISH TROUBLESHOOTING Problem Cause Solution No fuel Add fuel Generator will not start Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Fill crankcase to the proper level Low oil level Place generator on a flat, level surface Generator will not start;...
Page 29
Consequential Damage workmanship for a period of three years (parts and labor) from Champion Power Equipment disclaims any obligation to cover the original date of purchase and 270 days (parts and labor) for any loss of time, use of this product, freight, or any incidental commercial and industrial use.
Page 30
THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
Page 31
EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
Page 32
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.
Need help?
Do you have a question about the 100110 and is the answer not in the manual?
Questions and answers