thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instructions
1. SaFety
WarninG! ensure all Health and Safety, local authority, and general workshop practice regulations are strictly adhered to when
using this product.
iMPortant! noT FoR USe WITH ToXIC PAInTS SUCH AS ISoCYAnATe.
WarninG! Do not use in an oxygen deficient atmosphere (below 19% by volume).
WarninG! Do not use in an oxygen enriched atmosphere (above 25% by volume).
Respirator selection must be undertaken by a competent person who is aware of the intended conditions of use. Only fit the
9
respirator under the supervision of a competent person.
If in doubt as to suitability of the equipment for the work to be undertaken, consult your supplier.
9
Before use, check that the mask is clean and in good condition. If you detect deterioration of valve diaphragms, or other rubber
9
components, replace immediately.
Check that the correct cartridge is fitted to suit the hazard and that all components are correctly assembled and in a clean condition.
9
Change the main filter cartridge frequently. The effective life of a main filter should be determined by a competent person who is
9
aware of the conditions of use.
Ensure you use recommended parts only, unauthorised parts may be dangerous and will invalidate any warranty.
9
Only when worn correctly fitted will the mask provide the prescribed degree of protection.
9
Ensure the face-piece fits comfortably on the face.
9
WarninG! Mask may not fit correctly if facial hair passes under the face-seal.
Upon leaving the contaminated area, remove excess contamination from clothes before removing the respirator.
9
After each working period, the respirator must be cleaned and prepared for the next period of use.
9
Ensure you use only recommended filters.
9
Do not use detergents, thinners, solvents or petroleum-based disinfectant to clean the respirator. Clean the unit with warm soapy
8
water only.
Do not allow water to get into the main filter.
8
Care must be taken to ensure the rubber seal on the inside of the filter holder is not damaged.
9
Ensure you keep records of respirator maintenance.
9
When not in use, store the cleaned respirator in a sealed plastic bag in a clean, dry atmosphere out of direct sunlight and out of the
9
reach of children.
2. introDuction
Twin cartridge half mask with low resistance exhalation valve for easy breathing. Fully adjustable four-point suspension harness with quick
release. Comfortable and durable thermoplastic rubber face mask offering a superior fit to most face shapes and conforms to EN140.
Reflective strips for increased visibility in low light areas. Fitted with twin filters that confirm the correct fitting of the mask and conform to
EN14387:2004+A1:2008. Ideal for a variety of painting, welding, construction and wood cutting tasks. Filter Kit - Set of A2P3 cartridges for
SSP1605.
3. SPeciFication
Model No (filters): ................................................SSP1605FP
nett Weight: ..............................................................0.235Kg
4. oPeration
4.1.
chanGinG the Filter
note:
If you remove either of the filters and put them back on, check
the foam seal has not been damaged.
4.1.1.
Align the arrows (fig.1), press and twist the filter to the right until
it clicks.
4.2.
DurinG uSe.
4.2.1.
In the interest of safety, change the filter frequently.
4.2.2.
The effective life of the filter should be determined by a
competent person who is aware of the conditions of use.
4.2.3.
Upon leaving the contaminated area, remove excess
contamination from clothes before removing the respirator.
© Jack Sealey Limited
Paint SPray reSPirator Deluxe MoDel
anD Filter Kit For SSP1605
SSP1605, SSP1605FP
Model no:
fig.1
Original Language Version
SSP1605,SSP1605FP Issue 1 16/01/19

Advertisement

loading

Summary of Contents for Sealey SSP1605

  • Page 1 SSP1605, SSP1605FP Model no: thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St edmunds, Suffolk. iP32 7ar 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for:

Ssp1605fp