6. Trouble Shooting

FAULT
Not running
No LED display
LED display on
but not running
LED display on,
compressor running,
not cooling
LED display on
Fault light flashing
Led display shows
Error codes
Refers to fault light error
1 Flash: LOW VOLTAGE ERROR
Cause:
• Battery is flat . Check with multimeter, 12 .70 Volts 100% charge, 12 .05V 50% charge,
10 .50V 0% charge .
• Faulty supply lead . Check that the plug and lead are not broken or frayed .
• Supply wiring not the correct size (refer to cable sizing chart below) .
• To rule out that the fridge is not faulty, try running it on a different power source, either
on 240 Volt supply or a different vehicle or battery .
2 Flash: FAN ERROR
Cause:
• Condenser fan drawing too many amps (over 1-amp peak) . Requires a replacement fan,
contact Evakool .
CAUSE
No power to unit
Faulty electronic
component
Faulty electronic
component
Compressor or
refrigerant problem
Refer to chart below
ER1
ER2
RECOMMENDED FIX
• Try on both 12V DC and 240 AC
• Maybe a faulty lead
• Try a different power supply
• Check circuit breaker or fuse
Contact Evakool
(07) 5492 7777
Contact Evakool
(07) 5492 7777
Contact Evakool
(07) 5492 7777
The unit has its own built in fault
finding system depending on
how many fashes per 5 flashes
This is a thermistor issue
contact Evakool (07) 54927777
9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAXI TRAC MT-45 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Related Products for EvaKool MAXI TRAC MT-45

This manual is also suitable for:

Maxi trac mt-60Maxi trac mt075-dx

Table of Contents