M12 Can-Bus Connector Details - MG Energy Systems MGHE240100 Manual

Lithium-ion he battery module
Table of Contents

Advertisement

M12 CAN-bus connector details

The HE Series have the option to contain M12 CAN-Bus connectors.
Connector details
The connectors used for connecting the CAN-bus are all of the same type, namely a circular M12 connector
with 5 positions and A-coded keying.
Pin
Description
1
Shield
2
V+
3
GND
4
CAN-H
5
CAN-L
Cables to be used for the battery system are typically referred to as NMEA 2000 or DeviceNet compatible
cables. The minimum requirements for cables are:
Twisted pair connected to pins 4 and 5 for communication with a minimum wire cross sectional area
2
of 0.2 mm
(24 AWG).
Pair of conductors connected to pin 2 and 3 for power and HVIL with a minimum wire cross sectional
2
area of 0.34 mm
Cable with braided shielding connected to pin 1.
NOTICE:
Do not use sensor/actor cables. They often don't have any twisted pairs and are
therefore not suitable for this application.
MG Energy Systems B.V. | Foeke Sjoerdswei 3 | 8914 BH Leeuwarden | The Netherlands
+31 (0)58 750 89 47 | info@mgenergysystems.eu | www.mgenergysystems.eu
Table 11 - Circular M12 connector with 5 positions A-coded details
(22 AWG).
Connector view
Innovation
in energy storage

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGHE240100 and is the answer not in the manual?

Questions and answers

Table of Contents