  • Page 1 ATI5100 Intrusion Arming Terminal Installation Building Technologies Fire Safety & Security Products...
  • Page 2 Technical specifications and availability subject to change without notice. © 2009 Copyright Siemens Switzerland Ltd We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our...
  • Page 3: Table Of Contents

    Table of contents About this document ..................4 Safety......................5 Target Group ....................5 General Safety Precautions ................5 2.2.1 General Information .................5 2.2.2 Transport..................5 2.2.3 Installation..................5 2.2.4 Service and Maintenance ..............6 Standards and Guidelines................6 EU-Directives ....................6 FCC .........................6 C-Tick ......................7 UL-Directives....................7 Technical Data ....................7 Recommended Cable Specifications ..............8 Details for Ordering ..................9 Package Contents ..................9...
  • Page 4: About This Document

    Customer Support Center: Intranet: Customer Support Center Internet: Worldwide contacts Email: fs.support.sbt@siemens.com Tel.: +49 89 9221 8000 Training courses Siemens Building Technologies Fire Safety & Security Products provides training courses for all products. Building Technologies 020_ATI5100_A6V10235012_a_en Fire Safety & Security Products 23.09.2009...
  • Page 5: Safety

    Safety Safety Target Group Target Qualification Activity Condition of the readers product Installer Technical training for Installs the product, Components of the electrical installations. individual components product are not yet of the product or installed or need to be replacement parts. replaced or modified.
  • Page 6: Service And Maintenance

    Standards and Guidelines EU-Directives This product complies with the requirements of the following European directives. The EU declaration of conformity is available to the responsible agencies at: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe Germany European Directive 2004/108/EC „Electromagnetic Compatibility”...
  • Page 7: C-Tick

    Technical Data Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which  the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ...
  • Page 8: Recommended Cable Specifications

    Technical Data Recommended Cable Specifications NOTICE Guideline for selecting cables The table provides a guideline for selecting an appropriate cable type only. Other cable types are also compatible with the system and can be used to achieve the same results. Communica- Recommended Cable Specifications tion Type...
  • Page 9: Details For Ordering

    Details for Ordering Details for Ordering Type Part no. Designation Weight ATI5100 S24246-F2605-A1 Intrusion Arming Terminal 0.38 kg Package Contents 1 x ATI5100  1 x Installation manual  Accessories pack  Description of Equipment Service Description The ATI5100 is an intrusion arming terminal that operates as a part of an integrated access control and security system.
  • Page 10: Product Overview

    Description of Equipment Product overview K1 L EOL A Product overview A Lugs G Screws for mounting B Printed circuit board H Screw for tamper contact C Screw terminal I Cable duct D Tamper switch K1-K3 Breakout pieces E Fixing screw for printed circuit board L Cable entry hole EOL Jumper X3 Jumper...
  • Page 11: Set Jumpers

    Description of Equipment Set Jumpers Jumper Description Value EOL TERMINATION (FLN System Bus) This link allows the RS485 bus communication channel to be terminated in lengthy comms lines – more than 100 m. X3 (1-2) Reset the ATI5100 retaining the unit’s firmware Interrupt the power supply to the unit for 1 sec.
  • Page 12: Installation

    Installation Installation Opening the housing 1. Loosen the screws by a couple of turns. Open unit 2. Push the lugs downwards and slightly lift the cover using a screwdriver. 3. Lift the cover by approx. 2 cm and push it upwards. Unit is opened Building Technologies 020_ATI5100_A6V10235012_a_en...
  • Page 13: Connecting Cables

    Installation Connecting cables It is recommended to use a cable type IYSTY (Twisted Pair) 2 x 2 x Ø 0.6 mm or larger diameter. 1. Insert the cable through the cable entry hole [ 10] in the base. 2. If necessary, carefully remove the breakout pieces [ 10] . 3.
  • Page 14: Mounting The Cover

    Installation Mounting the cover 1. Hook the top of the cover into the base and push downward. 2. Push back the upper part of the housing. 3. The two lugs on the base engage with the corresponding recesses in the cover. 4.
  • Page 15: Disposal

    Disposal Disposal All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health.
  • Page 16 Issued by © 2009 Copyright Siemens Switzerland Ltd Technical specifications and availability subject to change without notice. Siemens Building Technologies Fire & Security Products GmbH & Co. oHG Siemensallee 84 D-76181 Karlsruhe www.buildingtechnologies.siemens.com Document ID A6V10235012 Edition 08.12.2009...