PAMS Technical Documentation
power sampling circuit and the ability of the software to reliably track multiple power
levels during ramping. The two regions are from power level 15 through 7 and from 6
to 0. Provisions have been made in the service software to automatically track these
break points in the calculation of the intermediate power levels.
RF Block Specifications
For further information on the different ASICs.
– CRFU_2a |5|
– SUMMA |6|
– COBBA_GJP |7|
– CCONT |3|
– MAD2_PR1 |8|
– CHAPS |9|
GSM1900 Duplex Filter
Parameter
Transmit section
Passband
Maximum insertion
loss in passband
Maximum passband
ripple
Maximum VSWR
Terminating imped-
ance
Minimum attenua-
Freq. range
tions
1930...1940
1940...1990
3800...5730
Issue 1 03/01
Table 18: Duplex filter
1850...1910
o
2.0 (+25
C)
o
2.2 (-30...+85
C)
1.5
1.8
50
Att. (min)
15
17
32
Nokia Mobile Phones Ltd.
Receive section
1930...1990
o
3.4 (+25
C)
o
3.6 (-30...+85
C)
1.6
1.8
50
Freq. range
Att. (min)
0...1100
50
1100...1700
35
1700...1830
30
1830...1910
20
2010...2070
10
2070...2700
25
2700...5000
20
5000...6000
15
NSB-5
System Module
Unit
MHz
dB
dB
ohms
MHz/dB
MHz/dB
MHz/dB
MHz/dB
MHz/dB
MHz/dB
MHz/dB
MHz/dB