Nokia Customer Care
Rx Path Troubleshooting
Rx path
Faults
Measure DC test
points at Table 4. Is it
OK?
YES
Measure Rx RF test
points 1
at Table 5. Is it OK
YES
Measure Rx RF test
points 2
at Table 5. Is it OK
YES
Measure Rx RF test
points 3
at Table 5. Is it OK
YES
Connect System Simulator to MS
antenna.
Note:
•
U6010 is underfilled and can not be replaced.
•
Memory IC is underfilled and can not be replaced.
•
The Shielding Cover can not be reused after removal.
•
After using the heatgun, the domesheet needs to be replaced.
Issue 1 04/20
07
Check U6010
NO
Reheat solder joints of
NO
L605, C603
Reheat solder joints of
NO
C612, L611 and U6010
Reheat solder joints of
FL601
NO
NO
© 2007 Nokia Corporation
RF Description and Troubleshooting
Reheat solder joints of
NO
NO
Check Antenna Module
Company Confidential
1265 (RH-104)
U6010
Change U6010
Page 17