Summary of Contents for sugar-valley AQUASCENIC HD 1
Page 1
QUICK INSTALATION GUIDE AQUASCENIC DESCRIPTION With the Hydrolysis system we produce active agents like Oxygen, Hydrogen peroxide, OH, Ozone … on the bases of Water (H2O - with a minimum conductivity of 1000mS). While the Water passes through the hydrolysis cell these oxidative agents are produced by braking up the H2O molecule in its components.
Page 2
INSTALATION Electrical consumption TITANIUM CELL connection overheating Maximum Recommended Ensure all electrical connections are firmly fixed to avoid false contacts and consumption protection subsequent overheating of system components (Especially concerning the Hydrolysis HD 1 180W cell with usage above 33A). HD 2 228W 600W...
Page 3
AJINITIAL ADJUSTMENTS Initial adjustments Conductivity adjustments 1.Adjust the alkalinity between 90 and 110 ppm. In poorly conductive waters add 1Kg, of sodium chloride (NaCl) for every m3 of pool water. 2.Adjust the PH between 7,2 and 7,4 3.Adjust the chlorine between 1 and 1,5 ppm. IN POOLS WHICH RECEIVE LARGE AMOUNTS OF STRONG SUNLIGHT 30gr/m3 OF STABILYSER (Isocyanuric acid) MUST BE ADDED SHOULD the water be supplied from a well: shock...
SYSTEMS WITH REDOX CONTROL The Redox level advises us of the potential oxidization or reduction level and is used to determine the level of water sterilization. The parameters or Set Points are the minimum/maximum accepted REDOX levels before the titanium cell is connected/disconnected. Adjusting the ideal REDOX level (set point) is the last step in the AQUASCENIC start up sequence.
MENU ACCESS Displays Ionization level Accessing user menu Hydrolysis level pH Control HOLD FOR 3 SECONDS TO ACCESS Redox / Free chlorine control EXIT USER MENU Conductivity control User menu LEVEL OF Cu/Ag ION PRODUCTION DISPLAY To modify level RECOMMENDED VALUE BETWEEN 20-50 To confirm and change menu screen RECOMMENDED CONFIGURATION Pr30 OXIDISATION LEVEL...
TROUBLESHOOTING EXCESS OXIDATION in water Display blank *Lower Hydrolysis cell level. *Check On/Off switch is illuminated. *If your system includes AUTOMATIC REDOX CONTROL check REDOX *Check external 250mA fuse has not fused. SETPOINT. *Check electric supply: 210-230V 50Hz *Check REDOX probe and calibrate if necessary. *If problem persists contact TECHNICAL SERVICE.
This manual is also suitable for:
Aquascenic hd 2Aquascenic hd 3Aquascenic hd 4Aquascenic hd 5Aquascenic hd 6
Need help?
Do you have a question about the AQUASCENIC HD 1 and is the answer not in the manual?
Questions and answers