  • Page 1 LM10 POOL LIFT INSTRUCTION MANUAL...
  • Page 3: Table Of Contents

    • Water pressure check ..................3 • Handling .......................4 • Connection ......................5 • Testing ........................5 OPERATIONAL GUIDELINES ..............6 • Use of the LM10 ....................6 • Emergency stop ....................7 • Maintenance ....................... 8 • General instructions..................9 srsmith.com/au - 3...
  • Page 4: General Information

    Hydraulic Drive - Domestic water supply (with booster pump when required) Minimum pressure: 3.5 bars User Controls: Up-down controls on deck upright and platform handrail Movement: Manually removable and mobile, collapsible for storage Warranty: 2 Years Weight limit: 160kg 2 - LM10 INSTRUCTION MANUAL...
  • Page 5: Installation

    INSTALLATION INSTALLATION AREA The LM10 must be installed more than 2.5m from the edge of the pool. The lift should be installed in a properly lit area (200 lux min to the ground) and provision of additional auxiliary lighting if the 200 lux is not reached.
  • Page 6: Handling

    HANDLING Two operators are required for removing the LM10 from the pallet. Once unpacked, roll the LM10 to the installation area (Images 1 and 2). The position of center of gravity is indicated by the red arrow. Refer to the installation sheet for the installation of the fixing lugs or anchor boxes. (fixing lugs shown below) Set the position of the LM10 as shown in Images 4, 5 and 6.
  • Page 7: Connection

    INSTALLATION CONNECTION Connect the water supply to the connection point at the side of the LM10. (Images 7 and 8) Gradually open the supply valve. (Image 9) Ensure the water supply operating pressure is above 3.5 bars. Check for any leaks in the water supply network.
  • Page 8: Operational Guidelines

    OPERATIONAL GUIDELINES USE OF THE LM10 The LM10 must always be used under the supervision of an authorised person. The lift can be operated by the user while standing on the platform or sitting in a wheelchair dedicated to this use.
  • Page 9: Emergency Stop

    OPERATIONAL GUIDELINES EMERGENCY STOP The emergency stop is operated by closing the switch of the emergency stop valve located on the left side of the access plate. (Image 12) The action on this valve controls the instantaneous stop of any descent or ascent of the mobile platform.
  • Page 10: Maintenance

    • Cleaning of the plastic platform: As required General inspection points (see table below) • Inspect the general condition of the LM10. • Inspect movement controls (access button boxes and mobile tray). • Inspect that the water pressure is set correctly (3.5 bars minimum) •...
  • Page 11: General Instructions

    GENERAL INSTRUCTIONS GETTING STARTED Before pressurizing, check that the network pressure does not exceed 5 bars. Check that the emergency stop valve works properly. Check the control buttons function correctly (ascent and descent). Notify an authorised person in the event of abnormal functioning. Presence of an authorised person monitoring the lift is required during use.