Analog door phone

Advertisement

Quick Links

Analog Door Phone
Model ADP1
Installation and Use Manual
© 2004 Bogen Communications, Inc.
All rights reserved.
Specifications subject to change without notice.
54-2098-01B 0607

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADP1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bogen ADP1

  • Page 1 Analog Door Phone Model ADP1 Installation and Use Manual © 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2098-01B 0607...
  • Page 2 In the event of equipment malfunction, all repairs should be performed by Bogen or an authorized agent. It is the responsibility of users requiring service to report the need for service to Bogen or to one of our authorized agents. Service can be facilitated through our office at: Bogen Communications, Inc.
  • Page 3 The unit is telephone line powered and includes adjustable microphone and speaker vol- ume levels as well as a selectable Auto Answer feature to allow for remote monitoring. The ADP1 also includes an adjustable and defeatable call timer and can respond to forward disconnect signals.
  • Page 4 Answer) an incoming call.With the timer disabled, the call time will be unlimited and the ADP1 will not disconnect the call until a 300 ms or longer loss of loop current is detected. If the telephone line/phone system extension does not supply a loop cur- rent break when the calling party hangs up, then the call timer feature must be used (enabled).
  • Page 5 Wiring Phone Connection The ADP1 comes with an RJ11 wired to the pluggable terminal block. Connect the ADP1 to the phone system’s analog station line programmed for ring down operation using the RJ11 or directly to the screw terminals depending on how the lines are terminated.The connections to the terminal block are not polarity sensitive.
  • Page 6 The ADP1 is designed to fit in most standard dual gang electrical boxes. Make sure to use the proper box type for intended installation (e.g., flush or surface mount, indoor or outdoor location, etc.). Flush Mounting the ADP1 (Indoor/Outdoor) 1. Cut rough opening and install appropriate electrical box.
  • Page 7: Specifications

    Specifications Power: Telephone line powered (18V DC / 20 mA minimum) Timer Duration: 15 seconds to 2 minutes Loop Current Loss Disconnect: 300 ms minimum Ring Voltage: 40V AC RMS minimum REN: 0.7A Connections: 2-position pluggable terminal block Earth Ground lug Dimensions: 5"...
  • Page 8 In no event shall Bogen be liable for special, incidental or consequential damages (including, but not limited to, loss of profits, loss of data or loss of use damages) arising out of the manufacture, sale or supplying of products, even if Bogen has been advised of the possibility of such damages or losses.