RainSoft EC5 Series Owner's Manual

RainSoft EC5 Series Owner's Manual

Water treatment system
Hide thumbs Also See for EC5 Series:

Advertisement

WATER TREATMENT SYSTEM
The EC5 series is tested and certified by the WQA to NSF/ANSI 44 for the specific performance
claims as verified and substantiated by test data. See the performance data sheet for specific
reduction claims.
The EC5 series is tested and certified by WQA to NSF/ANSI 372 for "lead free" compliance.
The EC5 series is tested and certified by WQA to CSA B483.1 Standard.
EC5 SERIES
Rainsoft Division of Aquion, Inc
101 S. Gary Ave
Roselle, Illinois 60172
1.847.437.9400 or 1.800.860.7638
www.rainsoft.com
Part No.: 16842
Rev: F
08/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EC5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RainSoft EC5 Series

  • Page 1 EC5 SERIES WATER TREATMENT SYSTEM ™ The EC5 series is tested and certified by the WQA to NSF/ANSI 44 for the specific performance claims as verified and substantiated by test data. See the performance data sheet for specific reduction claims.
  • Page 2: Table Of Contents

    Table of Contents Information on Water Treatment Systems ..........3 Application Limitations................3 Operational Specifications ..............4 _ 6 Salt Requirements..................7 Resin Cleaners....................7 Maintenance Requirements ................ 7 Product Certification Information ............7 Installation Instructions ................ 8 _ 12 System Start Up ..................
  • Page 3: Information On Water Treatment Systems

    Questions? If you have any questions regarding the installation, oper- ation, or servicing of this system, please contact your local RainSoft Dealer. Your local RainSoft Dealer is familiar with your particular water conditions, and is able to address your concerns promptly and efficiently.
  • Page 4: Operational Specifications

    Operational Specifications Plumbing 3/4 inch to 1 1/4 inch I.D. Drain Line 1/2 inch I.D. Water Pressure 20 psi _ 120 psi (1.38 bar _ 6.89 bar) Operating Temperatures 40° F _ 100° F (4.4° C _ 37.8° C) Electrical Requirements A properly grounded alternating current supply (110 VAC 60 Hz or 230 VAC 50 Hz) is required for the operation of this system.
  • Page 5 Data Chart for ION-X 2000 V Resin The conditioners are efficiency rated according to NSF/ANSI 44. The efficiency of Cation Max. Tank Drain the conditioner is valid only at the stated Exchange Service High Medium Model Size Flow psi Drop Efficiency* salt dosage.
  • Page 6 Operational Specifications continued from page 5 Data Chart for ION-X 100 T Resin The conditioners are efficiency rated Cation Max. Drain according to NSF/ANSI 44. The efficiency of Tank Size Exchange Service High Medium Model Flow psi Drop Efficiency* the conditioner is valid only at the stated salt (inches) Resin Flow...
  • Page 7: Salt Requirements

    Please refer to the performance data sheets for specific reductions claims. The EC5 Series is tested and certified by WQA to NSF/ANSI 372 for “lead free” compliance. The EC5 Series is tested and certified by WQA to CSA B483.1...
  • Page 8: Installation Instructions

    Installation Instructions 1. Safety Precautions Important Note: For Massachusetts Residents Only: The Commonwealth of • To prevent an accident and/or injury, do not hoist the unit over Massachusetts Plumbing Code 248 CMR your shoulder. Use a hand truck to transport the unit. shall be adhered to.
  • Page 9 • Align the upper basket with the riser pipe and slowly lower the control valve onto the riser pipe, using a twisting motion. • Align the control valve with the tank. Push down on the control valve and continue to turn it clockwise until the valve o-ring seals against the tank.
  • Page 10 •Ensure that the bypass valve is in Bypass position. The valve handles should be perpendicular to the pipes (see figure 4). Figure 4 9. Install the Drain Line and Air Gap (Air Gap Not Supplied) • For all drain lines, use at least a 1/2 inch I.D. line. •Connect the drain line to the drain outlet on back of the valve, opposite the inlet connection (see figure 5).
  • Page 11 Install the Brine Safety Float Important Note: Not Applicable for EC5-CAB Models. • Insert the brine well into the brine tank (see figure 7.1). • Attach the brine well to the brine tank with the overflow elbow (see figure 7.2). •...
  • Page 12: System Start Up

    12. Install the Brine Overflow Line (indoors) • Run a 1/2 inch I.D.brine overflow line from the overflow elbow on the side of the brink tank to an approved drain (see figure 8). 13. Attach the Electrical Connection • Insert the barrel plug from the DC power supply into the mating jack in the back of the control box .
  • Page 13 Adding Salt to your Brine Tank 1) Fill your Salt Tank with Block Salt, Solar Salt (Pellet) or Potassium Chloride. The RainSoft standard brine tank can hold a max of 250 lbs. [113kg] or LEVEL 5.0 of Pellet form Salt and 200 lbs.
  • Page 14 STACK IN G BLOCK SALT - 25 lbs B LOCK S COR R ECT STACKING I NCOR R ECT STACKING 6" Incorrect Stacking Using Correct Stacking Using 8" - 25 lb Salt Blocks - 25 lb Salt Blocks Standard Block Dims Standard Block Dims - 8 x 6 x 8.5 - 8 x 6 x 8.5...
  • Page 15: An Overview Of The Regeneration Process

    An Overview of the Regeneration Process Your RainSoft EC5 Water Conditioner performs a periodic regeneration cycle to clean itself and restore its capacity. How often it regenerates depends on your water use, incoming water hardness, and several other factors, but 1 - 2 times a week is typical. An automatic regeneration will never occur more than once in a day, and is programmed to occur at a time when you are unlikely to be using water (late at night in most cases).
  • Page 16 CYCLE 2- Brine Make Up/Service After adding water to the brine tank, the valve returns to home posi- tion and waits for two hours. This time is adjustable, but two hours provide the optimum solution. This gives the salt plenty of time to dissolve and ensures that an accurate salt dose is used.
  • Page 17: Navigating The Menus

    Navigating the Menus The EC5 control uses a simple layout of up/down & left/right buttons in a cross pattern with an enter button in the center. We hope you will find this system intuitive and familiar, since it is similar to TV remote controls and other devices you already have.
  • Page 18: Salt Level

    1-5. For larger tanks, a regenerates salt scale sticker is available through your RainSoft Dealer, part number 19024. If you have changed the salt level and want to save the change, press the ENTER button to exit to the Main Menu. If you do not want to save a change, press the LEFT button to return to the Main Menu without saving.
  • Page 19 This alarm indicates a serious issue with the drive assembly or valve and requires service by a trained technician. • Other RainSoft products in your home, such as a drinking water system and a whole house filter, have filter elements or other components which eventually become exhausted and need replacement.
  • Page 20 Additional Systems: This item shows the status of additional RainSoft systems that may be monitored by your EC5 control. Dealer Info : This item shows your dealer’s name, phone number, and email address. When you are done reviewing items in the System Information Menu, use the LEFT button to go back to the Main Menu.
  • Page 21: Configure Setting

    The brine tank has separate scales for bag (pellet) or block. Choose levels 1-5. For larger tanks, a salt scale sticker is available through the salt form you use (pellet or block) so that the computer can prop- your RainSoft Dealer, part number 19024. erly calculate salt level.
  • Page 22 Setting the proper Time Zone is important to synchro- observed in your area. nize communication with the RainSoft Remind app. Time Zone is shown as an offset from UTC (Coordinated Universal Time). Here are the major U.S. time zone offsets: U.
  • Page 23: Wi-Fi Setting

    No SSID to the assigned IP address when connected to the home Wi-Fi Network. This item is informational only and cannot be changed directly See the section on setting up your RainSoft Remind app for more information . Setting Up Your Rainsoft Remind...
  • Page 24 “Settings” and “Wi-Fi.” Browse for available networks. You should see “RainSoft EC5.” Choose to connect to “RainSoft EC5.” Return to the RainSoft Remind App. Press “Connect EC5 to Network” at the bottom of the screen. Enter your home network Wi-Fi SSID and password in the appropriate fields, then press “Connect to Network.”...
  • Page 25: Troubleshooting Guide

    2. Excessive water pressure. 2. Install a pressure regulator. If the troubleshooting guide did not resolve the symptom, please contact your local RainSoft Dealer for service. If you cannot locate your local RainSoft Dealer, please contact RainSoft Customer Service at 1-800-860-7638 or logon...
  • Page 26: Exploded Views And Parts Lists

    Valve Exploded View...
  • Page 27 Valve Parts List Item Quantity Part Number Description 17863 Composite valve body 17864 Spacer end 17865 Internal spacer 17866 Internal seal 18160 Retainer & down flow piston 10258 O-ring - 017 17869 End plug assembly 17870 10-24 x .812 screw hex washer head 17871 Piston rod 17887...
  • Page 28 Control Exploded View...
  • Page 29 Control Parts List Item Quantity Part Number Description 51920 GEN 5-REAR HOUSING ASSEMBLY 51921 RPS MOTOR GEAR DRIVE ASSEMBLY 17501 BRINE GEAR/CAM 51918 SCREW 1/4-20X 1in PAN HEAD PHIL SS 51902 GEN 5-REAR COVER 52106 EC5-FRONT HOUSING ASSEMBLY 51904 GEN5-DOOR EC5 51919 SCREW #4-20x0.25in, PHIL PAB SS 51927...
  • Page 30: Performance Data Sheets

    THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL STANDARD 372 FOR LOW LEAD COMPLIANCE WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT THE EC5 SERIES IS TESTED AND CERTIFIED BY BEFORE PURCHASING A WATER TREATMENT UNIT, YOU WQA TO CSA B483.1 STANDARD.
  • Page 31: Warranty Information

    TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI BEFORE PURCHASING A WATER TREATMENT UNIT, YOU STANDARD 372 FOR LOW LEAD COMPLIANCE HAVE YOUR WATER SUPPLY TESTED TO DETERMINE YOUR THE EC5 SERIES IS TESTED AND CERTIFIED ACTUAL WATER TREATMENT NEEDS. BY WQA TO CSA B483.1 STANDARD.
  • Page 32 OR EXTRA COARSE ROCK OR SOLAR SALT MAY BE USED. DO NOT NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate USE GRANULATED SALT. CONSULT YOUR RAINSOFT DEALER FOR POTASSIUM CHLORIDE USE.
  • Page 33 The defective part(s) (or entire unit) will either be repaired or new RainSoft part(s) furnished, for a nominal charge to cover labor, handling, packing and the increase, if any, in the retail price of the part(s) since the date of purchase.
  • Page 34 ™ RainSoft Division of Aquion, Inc. 101 S. Gary Ave, Roselle, IL 60172 Main Switchboard: 1.847.437.9400 Customer Service: 1.800.860.7638 www.rainsoft.com ©2016 RAINSOFT, A DIVISION OF AQUION, INC.

Table of Contents

Save PDF