Page 1
Last version of this manual IP2159EN • 2021-07-05 Technical Manual Ditec DAB105 Swing doors (translation of the original instructions) www.ditecautomations.com...
Contents Subject Page General safety precautions EC Declaration of Incorporation Technical specifications Standard installation Dimensions Main components Installation 5.1 Preliminary checks 5.2 General information 5.3 Installation examples 5.4 Removing the cover Automation with articulated arm. 6.a DAS805PSA 6.b DAB805PSAF (for applications on fire doors) Automation preparation and fastening (Left-hand opening) Automation preparation and fastening (right-hand opening) 6.a.1 Fixing the arm DAB805PSA...
General safety precautions ATTENTION! Important safety instructions. Please follow these instructions carefully. Failure to observe the information given in this manual may lead to severe personal injury or damage to the equipment. Keep these instructions for future reference. This manual and those for any accessories can be downloaded from www.ditecautomations.com. This installation manual is intended for qualified personnel only •Installation, electrical connections and adjustments must be performed by qualified personnel, in accordance with Good Working Methods and in compliance with the current regulations •...
SE-261 44 Landskrona Sweden Declare under our sole responsibility that the type of equipment with name: Ditec DAB105 swing door operator Comply with the following directives and their amendments: 2006/42/EC Machinery Directive (MD), particularly the following essential health and safety requirements: 1.1.2, 1.1.3, 1.2.1, 1.2.2, 1.2.3, 1.2.4.2, 1.2.6, 1.3.9, 1.4.3, 1.7.2, 1.7.3, 1.7.4, 1.7.4.1, 1.7.4.2.
1. Technical specifications Ditec DAB105 Power 100-240V~ +10/-15% 50/60 Hz Consumption max. 75W Power supply for accessories 400 mA max. Power supply fuse F1-F2 2xT6.3A 250 V Opening time min. 3s / 0°-80° max. 6s / 0°-80° Closing time min. 3s / 90°-10°...
2. Standard installation Ref. Code Description Ditec DAB105 Electro-mechanical actuator Control panel DAB805PSA-PSAF Articulated movement arm (DAB805PSAF for applications on fire barriers) DAB805PLA Sliding movement arm DAB805PLAT Movement arm with three levers DAB805PLAB Sliding movement arm (break-out/anti-panic) Opening sensor COM400MHB...
4. Main components Ref. Code Description Base plate Gearmotor DAB105CU Control panel Power End stop Upper head Lower head Casing DAB905ESE Safety and pulse extension card (optional) DAB905ESA Extension card for safety functions (optional) Cable fastener Cable transit slits DAB905BAT Battery kit Encoder ON/OFF/HOLD OPEN switch...
5. Installation The given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices. Unless otherwise specified, all measurements are expressed in mm. 5.1 Preliminary checks Check the stability and weight of the door wing. Make sure it moves smoothly, without any friction (reinforce the frame if necessary).
5.3 Installation examples The DAB105 automation for swing doors can be installed on one swing door, on two swing doors, or on two swing doors with a double exit. DAB805CMP DAB805CMP DAB805SE2 5.4 Removing the cover Remove the casing [8] by loosening the screw [Z].
6. Automation with articulated arm. 6.a DAS805PSA Use the articulated arm for doors that open outwards (as seen from the automation side). ~400 Shaft extension DAB805SE2 DAB805SE5 DAB805SE7 6.b DAB805PSAF (for applications on fire doors) Shaft extension DAB805SE5F Arm expansion 0-100 DAB805TFL 100-215...
Operator should be attached using the top/centered bolt first, then follow pattern Automation preparation and fastening (right-hand opening) Right-hand opening • Prepare the set-up for fixing the automation to the wall, respecting the measurements shown in the figures above (with refer- ence to the hinge axis).
Operator should be attached using the top/centered bolt first, then follow pattern 6.a.1 Fixing the arm DAB805PSA min 550 NOTE: open the door slightly and tighten the screw of the arm support seat [A] at 16 Nm (as shown in the figure). If a torque wrench is not available, use a 90°...
6.a.2 Assembling the left-hand articulated arm • In the case of automations with left-hand opening, you must invert the assembly of the articulated arm as shown in the figure. 6.b.1 Fixing the arm DAB805PSAF min 550 Arm extension kit DAB805TFL 90°...
7. Automation with sliding arm DAB805PLA Use the sliding arm for doors that open inwards (as seen from the automation side). Shaft extension DAB805SE2 DAB805SE5 DAB805SE7 -20/130 Automation preparation and fastening (left-hand opening) Left-hand opening Cable inlet Ingresso cavo Ø16 •...
Page 19
Operator should be attached using the top/ centered bolt first, then follow pattern...
Automation preparation and fastening (right-hand opening) Right-hand opening • Prepare the set-up for fixing the automation to the wall, respecting the measurements shown in the figures above (with refer- ence to the hinge axis). • Drill a hole in the door wing, in line with the fixing for the sliding arm. •...
Page 22
Operator should be attached using the top/centered bolt first, then follow pattern NOTE: Do not change door stop for pull application. Adjust the open door stop [F], as indicated in paragraph 8.2.
7.1 Fixing the sliding arm DAB805PLA min 700 16Nm NOTE: open the door slightly and tighten the screw of the arm support seat [A] at 16 Nm (as shown in the figure). If a torque wrench is not available, use a hexagon wrench of the type shown in the figure, gripping it on the long side and tightening very firmly.
8. Connecting to the electricity supply Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with a contact opening distance of at least 3 mm must be fitted on the mains supply. Check there is an adequate residual current circuit breaker and overcurrent cut-out upstream of the electrical system.
9. Electrical connections DAB105CU SYNCHRONISATION OF DOUBLE DOOR WINGS ON/OFF/HOLD OPEN 24 V LOUT Lock-out for OPD (–) Motion sensor / safety mat Opening (controlled from ON/OFF XIMP HOLD OPEN) Opening IIMP DO NOT USE ERROR LED 2 3 4 SPTE OPSP CLSP POAS CLTQ 1 2 3 4 5 Fix the label to the terminal board, taking care to apply it in the cor-...
Contact Function / Accessory Description Mat safety means that: • a closed door will not open, if someone steps on the mat • an open door will not close, if someone steps on the mat • during opening, the door will continue to open, even if someone steps on the mat GND-MAT N.O.
9.3. Adjustments Trimmer Trimmer Description Door start-up The SPTE trimmer is used to make adjustments for the acquisition of the opening/closing stops when the door starts up. Spring tension adjustment The spring pre-tensioning is factory-set at 210°. The maximum pre-tensioning of the spring is 210°. A greater tension could damage the spring or overheat the motor.
Dip-switches Description Push & Go Disabled Enabled The manual pushing of the door activates an automatic opening operation. When DIP1 - PAG the door is closed, a closure thrust is maintained by the motor or the spring. Push and Go is not active in program selector setting DOOR CLOSED.
10. Extension unit DAB905ESE (optional) There is a command extension card for managing the electric lock / electric strike, function selector, batteries, key selector switch and night-time closure. BATTERIES Torx T10 24 V DAB905ESA OPEN Function selector EXIT Closed door timer Door released signal 5mm nut KRST...
Page 30
Contact Function - Accessory Description The closure of the contact activates an emergency closure operation. This command is active in every situation, and has priority over every other command. When the contact has reopened (with JUMPER J=ON), the door resumes operating as set by the selector.
Contact Function - Accessory Description N.O. INTERLOCKED DOORS Applications with interlocked doors are possible. For the connections, see paragraph 20. GND-KILL If JUMPER=ON, the panel makes an automatic reset after an emergency closure. EMERGENCY N.O. A DAB905RSD reset device can be connected to restore normal door operation following GND-KRST OPENING an emergency closure (JUMPER=OFF).
10.3 Adjustments Trimmer Trimmer Description Adjustment of the opening delay time, from 0 s to 3 s. With DIP3=ON, the door release is active throughout the opening delay. Dip-switch Description DIP1 Power supply to the electric lock / electric strike 12 V max 500 mA 24 V...
11. Extension unit DAB905ESE (optional) There is a command extension card for managing motion sensors, alarm indications and door status. Torx T10 Blanking DAB905ESA Relay output 24 V 1 A ("External error indication” or “Open door indication”, DO NOT USE see J1) DO NOT USE 5 mm...
11.2 Outputs and accessories Output Description Output for the power supply to the accessories 24V 400 mA max. 1 ... NOTE: the maximum absorption of 400mA corresponds to the sum of all the accessories installed. Connect a self-checking safety sensor on the door wing. Connect the closing side sensor to terminals 1-2 (GND-PIMP).
Jumper Error indication. A potential free contact COM/NO/NC for external error indication Open door indication, A relay output is used to indicate an opening cycle or a specific position of the door. The indication position is set by adjusting the inhibit/blanking potentiometer. Test on external sensor (GND-PDET) Test on internal sensor (GND-PIMP) No test...
12. Start-up The spring pre-tension is factory set to 210° and is normally not necessary to adjust. If adjustment has to be carried out, see 9.3. 12.1 Adjusting the door stop a. Close the door b. Turn the potentiometer SPTE to 0° (if not already on 0°). SPTE 0°...
f. Close the door by turning the potentiometer SPTE to 0° and let the door close. NOTE: Impulses are not accepted if SPTE is more than 0°. SPTE 0° 1. Micro switch 2. Lock kick cam 3. Stop block 4. Fine-adjustment screw 5.
12.3.1 One push / two pushes on the LEARN BUTTON (LRN) NOTE: Remain clear of swing path of door, as door may close rapidly. The door has no safety during auto-learn cycle. - One push (delayed opening) Push the button once. The door will open after 2 seconds and adjust the back-check and latchcheck automatically. - Two pushes (direct opening) Push the button twice.
13. Pre-configured parameters The DAB105 automation has 10 groups of pre-configured system-loaded parameters. The group of parameters set in the factory corresponds to number 1. To modify the group of parameters: 1. Disconnect the batteries (if installed). 2. Disconnect the mains power supply.
14. Advanced settings available on the control panel version in- dicated, or subsequent versions DAB105CU 0501123456 14.1 Increased thrust force on closure when an electric lock is fitted 1. Disconnect batteries if any. 2. Disconnect the mains. 3. Press the LEARN BUTTON (LRN) and keep it depressed. 4.
15. Door requisites for “Low Energy” use The DAB105 automation is factory supplied with the setting “maximum performance”. For Low Energy use modify the classification as shown in the table 1. Disconnect the batteries (if installed). 2. Disconnect the mains power supply.
16. Example of an application with a standard control panel Double wings connection DAB105 ON/OFF/HOLD OPEN PASS24 (XIMP) PASS24 (XIMP) 17. Example of an application with optional extension units Emergency closure Reset (DAB905ESE) Closing door timer (DAB905ESE) Battery Error indication or door open...
18. Synchronized doors (DAB905SYN) SORMONTO OVERLAP SFIORAMENTO SENZA SFIORAMENTO DOPPIA USCITA DOUBLE EXIT SKIM WITHOUT SKIM Connect the two automations to the plug on the control panel, using the synchronisation cable (DAB905SYN). Depending on the type of installation, cut the jumpers on the MASTER or SLAVE cable, as shown in the table: The MASTER automation is the one that opens first.
19 Example of installation of synchronized doors (DAB905SYN) INNER INNER FUNCTION FUNCTION OPEN SENSOR OPEN SENSOR SELECTOR SELECTOR SAFETY SAFETY SAFETY SAFETY SENSOR SENSOR SENSOR SENSOR SLAVE MASTER OUTER OUTER OPEN SENSOR OPEN SENSOR SLAVE MASTER DAB905SYN (see applications chapter 18) INNER OPEN SENSOR INNER OPEN SENSOR 24 V...
20. Interlocked automations This interlock function cannot be used if security is required Interlock connection. KILL= N.O. DOOR B MAGNET SWITCH DOOR A ( N.C) * DOOR A MAGNET MASTER SLAVE SWITCH ( N.C) * DOOR B Door B (+) 24 VDC OPEN (+) 24 VDC EXIT...
22. Troubleshooting Problem Possible cause Solution / Explanation The door does not open a) The motor does not start The function selector is set on OFF Change the function selector setting There is no mains power supply Check the mains power supply The command unit does not work Check the connections of the command ac- cessories...
Make sure the signs are in good condition, and attach them. Obligatory indicates that this sign is required by the European directives and equivalent national legislation outside the EEC. Ref. Description Product label. Obligatory. DAB105 ART. NO. TYPE YEAR+WEEK XXXXXXX...
Page 48
All the rights concerning this material are the exclusive property of ASSA ABLOY Entrance Systems AB. Although the contents of this publication have been drawn up with the greatest care, ASSA ABLOY Entrance Systems AB cannot be held responsible in any way for any damage caused by mistakes or omissions. We reserve the right to make changes without prior notice.
Need help?
Do you have a question about the DAB105 and is the answer not in the manual?
Questions and answers