Nokia NHL-2NA Series Troubleshooting Instructions page 73

Transceiver
Hide thumbs Also See for NHL-2NA Series:
Table of Contents

Advertisement

CCS Technical Documentation
Troubleshooting diagram for GSM900 receiver:
Apply –90dBm
942.46771MHz
signal from generator
to antenna connector
Yes
No
Oscilloscope at RX_I
Signal 700mVpp
DC offset 1.35V
Frequency 67.7kHz
Yes
EGSM RX chain
functional
Issue 1 07/02
Yes
Change
Spectrumanalyzer
generator
900 SAW i/p
level to
-61 dBm
–50dBm
Yes
Spectrumanalyzer
900 SAW o/p
-66 dBm
Yes
Oscilloscope
VR4 2.7V
Check Hagar
serial interface
(burst mode)
Yes
Spectrumanalyzer
VCO o/p
3769.6MHz
∼-37 dBm (*
Yes
Check Hagar
N505
¤Nokia Corporation
No
No
Spectrumanalyzer
900 ASM RX
-80 dBm
Yes
No
Oscilloscope
LNA_G 2.6V
LNAB_G 2.7V
Yes
Yes
Spectrumanalyzer
900 LNA o/p
–57 dBm
No
No
Oscilloscope
900 LNA o/p 2.6V
900 LNA i/p 0.8 V
Yes
Check V610,
C597, L566, L567
No
Check Z600,
C599, C601, L600
No
Check Baseband
No
Synthesizer
troubleshooting
NHL-2NA
Check
Antenna
switch
Z672
No
Oscilloscope
Check
VR4 2.7V
Baseband
Check Hagar
serial interface
Check R612
Yes
Check Hagar
N505
Check C610
Check V610,
L610, R616
All spectrumanalyzer
reading values are
measured with 1 kohm
passive probe (use
tweezers to connect the
probe ground to the
nearest PWB ground).
Reading value is
represented without +26
dB compensation.
* Spectrumanalyzer
reading with 1 kohm
passive probe (right
value add +26 dB)
Page 7

Advertisement

Table of Contents
loading

Table of Contents