Table of Contents Introduction ................................ 5 Using the applicator ............................5 Included Items..............................6 Specification ..............................6 Noise information............................6 Equipment Description ........................... 6 General safety instructions ..........................8 Workplace Environment ..........................8 Specific safety instructions..........................8 Operating instructions ............................9 Setup ................................
Page 4
The following symbols are found in this manual. Read the User Manual! Follow safety warnings and instructions! Protect yourself from electric shock. Use Caution! Keep children away from the machine while in operation! Risk of electric shock when a power cord is damaged! Dispose of the packaging and the appliance in accordance with environmental regulations! Phone: US 888-215-3966...
Introduction Before using the machine for the first time, get acquainted with the functions of the machine and be informed about the correct operation with electrical appliances. Read the following operating instructions. Follow the instructions in the manual. When handing over the machine to third parties, include all documentation.
General safety instructions Attention! The following safety precautions must be observed when using electrical appliances to protect against electric shock, risk of injury and fire. Read all of these instructions before using the machine. Workplace Environment - Ensure good lighting in the workplace. - Do not use the appliance in humid conditions.
Operating instructions Attention! Every operator working with the label applicator should become acquainted with this user manual. Setup The machine should be placed on a flat, horizontal surface larger than its base. You should provide space around the machine for maintenance servicing and handling. From the kit supplied with it, a power cord is connected to the supply socket and also a 'start pedal' is connected to an external start coupling.
Page 10
2. Lift the stoppers to remove them. There will be washers on the bolts. Leave these in place. 3. Install the stoppers, reversing their position. The tabs will be on the inside. Install the washers. 4. Install the thumb screws. Phone: US 888-215-3966 EU: 44.845.230.7800 www.afinialabel.com...
The online tool to calculate the values can be found on our website, https://afinialabel.com/calculate-a200. This QR code will take you to the webpage. When applying a single label, see page 14 to manually calculate the parameter value.
Working with the menu and changing parameters To gain access to the menu, hold down the key for 3 seconds. Once in the menu, parameters for one label and two label applications can be set. For the one label mode, Offset Stop and Time Move Motor values can be set. For the two label mode, label gap size, distance between labels, offset stop 1, offset stop 2 and Time Move Motor values can be set.
Adjustment of the label sensor The label stock and matrix must travel through the sensor area. If irregular shaped label stock is used, the sensor will not register the gap correctly. When calibrating, the label stock cannot be moving. 1. Position the stock so that the gap is under the sensor, as shown in figure 3.2 2.
This value needs to be determined when applying one label. The easiest way to do this is to use the online tool on our website, https://afinialabel.com/calculate-a200. This QR code will take you to the webpage. To manually determine the value, follow these steps.
) label, when applying two labels to a container. The easiest way to do this is to use the online tool found on our website, https://afinialabel.com/calculate-a200. This QR code will take you to the webpage. To manually determine the value, follow these steps.
This value determines the correct position of the front (1st) label, when applying two labels to a container. The easiest way to do this is to use the online tool on our website, https://afinialabel.com/calculate-a200. This QR code will take you to the webpage. L = 100mm, the distance between the label sensor and the peeling edge.
Memory Locations There are 29 memory locations that can be used to store job parameters. Once a memory location is selected, enter in the job parameters, as described below. Once the parameters are saved, that memory location can be recalled, to run that particular job in the future. To enter the memory location menu, press and hold the <...
ONE LABEL mode parameters There are two parameters associated with the one label mode, Offset Stop and Time Move Motor. Refer to page 13 to manually determine the Offset Stop value. The Time Move Motor value is the amount of time the container will turn, to apply the label. The easiest way to do this is to use the online tool found at this website: afinialabel.com/…..
TWO LABEL mode parameters There are five parameters associated with the two label mode, Labels Gap, Distance labels, Offset Stop 1, Offset Stop 2 and Time Move Motor. Refer to pages 14 and 15 to manually determine the Offset Stop values. The Time Move Motor value is the amount of time the container will turn, to apply the label.
When applying two labels, the distance between label one and label two needs to be entered into the applicator. The easiest way to do this is to use the online tool on our website, https://afinialabel.com/calculate-a200. This QR code will take you to the webpage. To calculate this value manually, follow these steps.
Maintenance and cleaning Attention! Risk of Injury! Always disconnect the power cable form the machine before performing any work on the device. The applicator does not require hardware maintenance for normal operation. Clean the machine after each job is completed. ...
Warranty Below is the one-year limited warranty included with this Afinia product. Afinia prides itself on its outstanding product line and its technical support. If for some reason, your product fails, Afinia, a division of Microboards Technology, LLC, stands behind its warranties and assures you the best service possible in a quick and timely manner.
Regulatory Details FCC Statement NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
PH: 952-556-1608 PH: +44 (0) 845 250 7949 support@afinia.com support@afinia.co.uk www.afinialabel.com/support www.afinialabel.com/support Please have the Serial Number of your Afinia A200 Label Applicator available when contacting Technical Support. Date of Purchase: Place Purchased: Serial Number: Phone: US 888-215-3966 EU: 44.845.230.7800...
Need help?
Do you have a question about the A200 and is the answer not in the manual?
Questions and answers