Adjustment - Sharp CD-BP2000W Service Manual

Hide thumbs Also See for CD-BP2000W:
Table of Contents

Advertisement

CD-BP2000W/210W/2000A/BK2000W/210W
CD MECHANISM SECTION
Perform steps 1, 2, 3, 12, 13, 14 and 15 of the disassembly
method to remove the CD mechanism.
How to remove the loading motor
(See Fig. 14-1)
1. Bend the hooks (A1) x 5 pcs., to remove the loading motor.
How to remove the pickup (See Fig. 14-2)
1. Remove the stop washer (B1) x 1 pc., to remove the gear
(B2) x 1 pc.
2. Remove the screws (B3) x 2 pcs., to remove the shaft (B4)x
1 pc.
3. Remove the pickup.
Note
After removing the connector for the optical pickup from the
connector, wrap the conductive aluminium foil around the
front end of connector remove to protect the optical pickup
from electrostatic damage.
MECHANISM SECTION
• Driving Force Check
Torque Meter
Play: TW-2111
• Torque Check
Torque Meter
Play: TW-2111
30 to 80 g. cm
Fast forward: TW-2231
Rewind: TW-2231
All manuals and user guides at all-guides.com

ADJUSTMENT

Specified Value
Tape 1: Over 80 g
Tape 2: Over 80 g
Specified Value
Tape 1
Tape 2
30 to 80 g.cm
70 to 180 g.cm
70 to 180 g.cm
Stop Washer
(B3) x2
(B1) x1
ø2.6 x6mm
Shaft
Gear
(B4) x1
(B2) x1
• Tape Speed
Test Tape
Normal
MTT-111
speed
TAPE MECHANISM
Variable Resistor in motor
– 14 –
Loading Motor
(A1)x1
(A1)x2
(A1)x2
CD Base
Figure 14-1
Pickup
CD Mechanism
Figure 14-2
Adjusting
Specified
Instrument
Point
Value
Connection
3,000 ±
Variable
Speaker
Resistor in
30 Hz
terminal
motor.
(Load
(MM1)
resistance:
6 ohms)
MM1
Motor
Figure 14-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cd-bp210wCd-bp2000aCd-bk2000wCd-bk210w

Table of Contents