©2020 Lennox Industries Inc.
Dallas, Texas, USA
THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
General
This SL28XCV outdoor air conditioner with all-aluminum
coil is designed for use with HFC-410A refrigerant only.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
THIS UNIT IS A INTEGRAL COMPONENT OF A SYSTEM THAT
WILL REQUIRE A COMMUNICATING THERMOSTAT AND
COMMUNICATING AIR HANDLER OR FURNACE.
Communicating air handler
or furnace
SL28XCV
This unit must be installed with an approved indoor air
handler or coil. For AHRI Certified system match-ups and
expanded ratings, visit www.LennoxPros.com.
SETTING THE UNIT – Clearances
CLEARANCE ON ALL SIDES — INCHES (MILLIMETERS)
6 (152)
12 (305)
36 (914)
MINIMUM CLEARANCE BETWEEN TWO UNITS
Communicating
thermostat
NOTES:
Clearance to access panel must be 30
CONTROL
inches (762mm).
PANEL ACCESS
Clearance to one of the other three
LOCATION
30 (762)
sides must be 36 inches (914mm).
Clearance to one of the remaining two
sides may be 12 inches (305mm) and
the final side may be 6 inches
(152mm).
Note: Dimensions are not to scale.
24
(610)
INSTALLATION
INSTRUCTIONS
Dave Lennox Signature
Collection SL28XCV System
AIR CONDITIONER
508022-01
3/2020
PACKING LIST
GROMMETS (2) BUSHING (1)
OUTDOOR UNIT
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, or service agency.
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 20 in this
instruction for information.
LINE SET
CONNECTIONS
Page 1
®
WARRANTY
RAST 6-PIN
CARD
CONNECTOR (1)
WARNING
MINIMUM CLEARANCE
ABOVE UNIT
48 (1219)
ACCESS
PANEL
REAR VIEW OF UNIT