--TroubleShooting

Problem or Concern
The indicator is not on.
The compressor doses not
start.
The indicator is on ,but the
compressor doesn't work and
buzzes only
The compressor stops a minute
after start, and restart after a
few minutes, and so repeatedly.
The
compressor
normally, but the temperature
in the cabinet goes down too
slowly.
The noise is too loud
The following are not faults:
When the freezer is working or after is stops for a while, the refrigerant in the pipes is cycling and gives out
running water"sounds.
The surface temperature of the compressor may be up 150°F when it is working.
The back side of step freezer gives out heat.
In rainy season, the outer surface of the cabinet may have dew, which makes no defects on normal use. Just
dry it with a piece of cloth.
Possible Cause
The plug isn't connected to the
socket really.
no power
The power voltage is<98V.
The power voltage is>132V.
The
door
is opened
frequently.
The food in the cabinet is too
works
much, and placed improperly.
The frost layer is too thick.
The surface of the condenser is
too dirty.
The door seals badly.
The freezer is placed unstably.
The fixing of the freezer is
loose.
there's contact between pipes.
Common Solution
Replug it.
Connect the socket with power.
Connect
(with
capacity).
too
Reduce open times.
Place foods properly keep place
between them for ventilation of
cold air.
Take out foods and defrost.
Stop and clean the condenser.
Adjust the door seal.
Place it stably.
Tighten the fixing.
Separate them.