Sea Tel COBHAM Installation And Operation Manual
Sea Tel COBHAM Installation And Operation Manual

Sea Tel COBHAM Installation And Operation Manual

Marine radome air conditioner

Advertisement

Sea Tel Marine Radome Air Conditioner
Installation and Operation Manual
Sea Tel, Inc.
(trading as Cobham SATCOM)
4030 Nelson Avenue
Concord, CA 94520
Tel: +1 (925) 798-7979
Fax: +1 (925) 798-7986
Web:
http://www.cobham.com/satcom
December 15, 2017
Thrane and Thrane A/S
(trading as Cobham SATCOM)
Lundtoftegaardsvej 93 D, 2800 Kgs.
Lyngby, Denmark
Tel: +45 3955 8800
Fax: +45 3955 8888
Email:
satcom.ohc@cobham.com
Document No. 99-158223-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COBHAM and is the answer not in the manual?

Questions and answers

Summary of Contents for Sea Tel COBHAM

  • Page 1 Sea Tel Marine Radome Air Conditioner Installation and Operation Manual Sea Tel, Inc. Thrane and Thrane A/S (trading as Cobham SATCOM) (trading as Cobham SATCOM) 4030 Nelson Avenue Lundtoftegaardsvej 93 D, 2800 Kgs. Concord, CA 94520 Lyngby, Denmark Tel: +1 (925) 798-7979...
  • Page 2 The information contained in this document is proprietary to Sea Tel, Inc. This document may not be reproduced or distributed in any form, without prior written consent of Sea Tel, Inc. The information in this document is subject to change without notice. Sea Tel Inc. is also doing business as Cobham SATCOM.
  • Page 3 Sea Tel Marine Radome Air Conditioner Revision History ECO# Date Description December 15, 2017 Production Release...
  • Page 4 Sea Tel Marine Radome Air Conditioner This Page Intentionally Left Blank...
  • Page 5: Table Of Contents

    Introduction Sea Tel Marine Radome Air Conditioner 1. INTRODUCTION ..........................1-2 1.1............................1-2 ANUAL 1.2..................... 1-2 BOUT THE ARINE ONDITIONER 1.3. FOR YOUR SAFETY ........................... 1-2 2. INSTALLATION ..........................1-4 2.1......................... 1-4 NTERNALLY OUNTED NITS 2.2........................ 1-5...
  • Page 6: Introduction

    Sea Tel Marine Radome Air Conditioner Introduction Introduction Congratulations on your purchase of the Marine Radome Air Conditioner. We sincerely appreciate your support of our company and the trust you’ve placed in our products 1.1. This Manual Please be sure to thoroughly read this manual to the end before commencing operation of the unit. Store it in a place where it is easily accessible.
  • Page 7 Introduction Sea Tel Marine Radome Air Conditioner When carrying or moving the unit, please keep it level and balanced and adapt your movements to the shape and weight of the unit at all times. If the unit is dropped, there is a risk of injury and other accidents.
  • Page 8: Installation

    Sea Tel Marine Radome Air Conditioner Installation Installation This section covers the installation procedures for internally and externally mounted Radome systems. Please note that the following instructions are intended as a general guideline only. You MUST read and refer to the antenna’s system installation and operation manual for detailed information.
  • Page 9: Externally Mounted Units

    Installation Sea Tel Marine Radome Air Conditioner 2.2. Externally Mounted Units If you are installing an externally mounted Marine Radome Air Conditioner, select a location near the dome to keep the evaporator ducting as short and straight as possible. NOTE: Ensure that the condenser openings are clear from obstructions.
  • Page 10: Digital Lcd Control Panel

    Sea Tel Marine Radome Air Conditioner Digital LCD Control Panel Digital LCD Control Panel The Marine Radome Air Conditioner uses an advanced Digital LCD Control Panel. The display uses a colorful screen to show set-point temperature and is easy to operate.
  • Page 11: Button And Indication

    Digital LCD Control Panel Sea Tel Marine Radome Air Conditioner 3.2. Button and Indication Button Description Single button press: ON/OFF Turns power on and power off when pressed each time ▲ Increase temperature set-point value. (Range: 17°-30°) ▼ Decrease temperature set-point value. (Range: 17°-30°)...
  • Page 12: Inspection And Operational Notes

    Sea Tel Marine Radome Air Conditioner Inspection and Operational Notes Inspection and Operational Notes Please read this section carefully before using the Marine Radome Air Conditioner to ensure safe operation. If any fault or malfunction is discovered, please take appropriate measures immediately.
  • Page 13: Compressor Overload Protector Notes

    Inspection and Operational Notes Sea Tel Marine Radome Air Conditioner 4.2. Compressor Overload Protector Notes • The overload protector is used to protect the compressor from over drawing current and overheating. • Ambient temperatures over 50°C will cause the protector will trip, thus protecting the compressor.
  • Page 14: Troubleshooting & Maintenance

    Sea Tel Marine Radome Air Conditioner Troubleshooting & Maintenance Troubleshooting & Maintenance 5.1. Problems and Solutions Problem Possible Reasons & Solutions Cannot start the machine 1. The power is off due to an emergency. Press ON/OFF button until the power is recovered.
  • Page 15: Maintenance

    Troubleshooting & Maintenance Sea Tel Marine Radome Air Conditioner Fan is not running but the 1. Fan capacitor is damaged. compressor is running Troubleshoot fan capacitor, call local dealer or service to replace or repair. 2. Wiring disconnected or loose.
  • Page 16: Main Pcb Wiring Diagram

    Sea Tel Marine Radome Air Conditioner Troubleshooting & Maintenance 5.3. Main PCB Wiring Diagram 5.4. Controller Wiring Connection Diagram 5-12 99-158223-A...
  • Page 17: Product Diagram

    Troubleshooting & Maintenance Sea Tel Marine Radome Air Conditioner 5.5. Product Diagram 5-13 99-158223-A...
  • Page 18 Troubleshooting & Maintenance Sea Tel Marine Radome Air Conditioner This Page Intentionally Left Blank 99-158223-A...
  • Page 19: Specifications

    Specifications Sea Tel Marine Radome Air Conditioner Specifications Sea Tel Marine Air Conditioner Physical Dimensions 762 x 367 x 838 Input Voltage 220-240 VAC, 2A-1A, 50-60Hz, Input Power Consumption 1700W (2100W Max) Weight 55 kg (121.3 lbs) Protection Class IPX4 Full Load Amps 7.7A (9.5A Max)
  • Page 20: Drawings

    Drawings Sea Tel Marine Radome Air Conditioner Drawings 7.1. Sea Tel Marine Air Conditioner Drawings Drawing Title 88-207254-000 Air Conditioner, External, Outline Demensions 37-156302 Power Cord, Cir./BRK to Air Conditioner, 6ft. 97-158189 Installation Instructions, Internal Air Conditioner 99-158223-A...
  • Page 21 Sea Tel Marine Radome Air Conditioner Drawings This Page Intentionally Left Blank 99-158223-A...
  • Page 22 Sea Tel - Strictly Confidential & Proprietary. Do Not Copy, Distribute or Disclose Without Prior 1:10 88-207524-000 USE ELSEWHERE). Written Approval From Sea Tel. 3rd ANGLE XX97 1 OF 1 Copyright c Sea Tel, Inc 2011 - Unpublished Work FIRST USED: SHEET NUMBER PROJECTION...
  • Page 23 BILL OF MATERIAL I.D. UOM Qty PART NUMBER DESCRIPTION VENDOR PART # VENDOR 115554-6 POWER CORD, SHIELDED W/ DRAIN, 14 AWG 19364 BELDEN 121899-14 TERMINALS, PIN, 14 AWG, GRY 9004730000 WEIDMILLER 111398-2 SPADE TERMINAL, BLU INSULATED, #6, 18-14 AWG. 14RB-6F THOMAS &...
  • Page 24 UNLESS INITIALLED & DATED BY DRAWN BY INSTRUCTION NUMBER: REV. 97-158189-A Sea Tel - Strictly Confidential & Proprietary. Do Not Copy, Distribute or DOCUMENT CONTROL OR DESIGNATE. JWM. Disclose Without Prior Written Approval From Sea Tel. SHEET 1 OF 5...
  • Page 25 Prepping the base pan before shipment: 1. Install item 3 Roxtech EzEntry 10/10 cable gland Kit using a Phillips head screw driver and the hardware that comes with the kit. 2. Install item 4 DRAIN HOSE STRAIN RELIEF KIT using channel lock pliers. 3.
  • Page 26 4. Install the new AC with the outside exhaust face the new vent hole using a 7/16 wrench & socket wrench. 5. Using item 20 through 29 & Loctite, the 1/4 – 20 bolts, are to be torque to 50 in oz. 6.
  • Page 27 7. Install the drain hose: a. Install the 90degree pipe fitting with the channel locks pliers. b. Work the hose on to the fitting. c. Slide the clamp over the hose and fitting and tighten with the flat tip screw driver as shown.
  • Page 28 10. Route the power cable to the air-conditioner circuit breaker. INSTRUCTION NUMBER: REV: 97-158189-A SHEET 5 OF 5...