Fujitsu UTW-SCBYA Installation And Operating Manual page 23

Table of Contents

Advertisement

Line
Function
Additional generator (Boiler connection)
3700
S
Release under outdoor temperature
3705
S
Overrun time
3720
S
Switching integral (for boiler relief)
Domestic hot water (DHW) (Only with the DHW kit option)
5020
S
Flow setpoint boost
5024
S
Switching diff
5030
S
Charging time limitation
5060
S
Electrical resistance regime
5061
S
Electrical resistance release
Installation configuration
5700
I
Pre-setting
This control enables you to choose one of the 4 pre-selected installation configurations. The hydraulic layouts for the
various configurations are detailed in the section : "Installation Configurations".
- Pre-setting 1 : 1 heating circuit
- Pre-setting 2 : 1 heating circuit and DHW tank.
- Pre-setting 5 : Boiler connection and 1 heating circuit.
- Pre-setting 7 : Boiler connection, 1 heating circuit and DHW tank.
- Pre-setting 3, 4, 6, 8 to 12 : Do not use for monobloc heat pump.
5711
S
Cooling circuit 1
4-pipe system is not compatible with the heat pump. Select 2-pipe system to activate cooling operation
5870
S
Combi storage tank
5987
S
Cont type input EX4
5989
S
Cont type input EX5
6046
I
Function input H2
1 - Operating mode change HCs + DHW
2 - Operating mode change HCs
3 - Operating mode change HC1
6 - Error/alarm message
9 - Dew point monitoring
16 - Swimming pool release
6047
I
Contact type H2
6048
S
Function value contact H2
6100
S
Readjustm outside sensor
6120
S
Frost protection plant
6205
S
Reset to default parameters
6220
S
Software version (RVS)
Fault
6711
U
Reset HP
6740
S
Flow temp HC1 alarm
6745
S
DHW charging alarm
6746
S
Flow temp cooling 1 alarm
Installation and operating manual "1395 - EN"
Setting range or display
--, -50... 50 °C
0... 120 min
0... 500 °Cmin
0... 30 °C
0... 20 °C
10... 600 min
Substitute, Summer, Always,
Cooling mode
24h / day, Release of DHW,
Programme 4 / DHW
1,2,3,... 12
Off, 4-pipe system,
2-pipe system
No, Yes
Normally-closed contact (NC)
Normally-opened contact (NO)
Normally-closed contact (NC)
Normally-opened contact (NO)
1... 16
NC - Normally-closed,
NO - Normally-opened
0... 130 °C
-3... 3 °C
On, Off
No, Yes
0... 99
No, Yes
--, 10... 240 min
--, 1... 48 h
--, 10... 240 min
Control Box
Setting
Basic setting
increment
0,5 °C
2 °C
1 min
20
1 °Cmin
100 °Cmin
1 °C
5 °C
1 °C
7 °C
10 min
90 min
Substitute
Release of
DHW
1
1
Off
No
NO
NC
1
9
NO
1 °C
45 °C
0,1 °C
0 °C
On
No
No
10 min
--
1 h
--
10 min
--
- 23 -