Quick Installation Guide
MPEG-2 & 1 ENCODER
1
Getting Started
The Encoder's IP address, as well as basic video settings, are required as the video channels are disabled when shipped
from the factory. These configuration settings are set via the serial interface or a Telnet session. Once the IP address is set,
the configuration can proceed using the serial interface, Telnet, Impath i-Volution NMS or via an SNMP manager.
Serial local console access
Requirements:
PC workstation with a RS 232 serial interface
PC workstation capable of running terminal emulation program. (example, Windows HyperTerminal).
PC serial cable - DB9 Male to Female. This cable is available from any PC supply store
Set the Terminal Emulation application for 9600 bps, 8 bit, no parity on appropriate COM port.
Connect to
COM port
PC Workstation
Terminal Emulation Application
9600 Bps, 8 bit, no parity
No flow control
Connect the serial cable between the Encoder serial Port "A" (also labeled Console) and your workstation COM port.
Start the Terminal Emulator (Windows Hyper Terminal) application
Press and hold the "console" button on the unit for 6 to 8 seconds until the data LED on the unit turns amber (yellow)
At this time, the message "CONSOLE>" will appear on the workstation screen.
At the CONSOLE> prompt enter "maint"
The "MAIN MENU" prompt will appear.
Go to step 2
or
Telnet console access
Requirements:
PC Workstation with an Ethernet interface (10/100BaseT)
PC Workstation must be connected to the Ethernet network using a valid IP address for the Ethernet network.
If connected directly to the Encoder, a crossover Ethernet cable is required
Connect Ethernet
cable to RJ 45
Ethernet ports
PC Workstation
From the Windows Start menu
select RUN and type in
telnet <IP address>
NOTE: After each entry, press the
Use Windows Start > RUN to launch a Telnet session.
Enter
"telnet _ _ _ . _ _ _ . _ _ _ . _ _
At the "LOGIN" prompt, enter the username. The default value is "impath"
At the "Password" prompt, enter the unit password. The default value is "impath"
At the "REMOTE-CON>>" prompt, enter "maint"
The "MAIN MENU" prompt will appear.
Go to step 2
i4000
DB9 serial cable
<ENTER>
i4000
Ethernet Cable
<ENTER>
key on the PC keyboard.
_" Enter the Encoder IP address
i1000, i1200, i1400
Connect to Port A
of Encoder
i1000, i1200, i1400
Ethernet RJ 45 port
VSG-L
VSG
Locate "Console" button
in front of Encoder
VSG-L
VSG
Need help?