SANUSLIFE ECAIA S Operating Instructions Manual

Ionizer faucet

Advertisement

Quick Links

EN Operating instructions
Long version
Version 21.06.30
Operating instructions (EN)
ionizer S faucet
Additional faucet for ECAIA ionizer S
Additional operating instructions to be used in combination with
User manual for the ECAIA ionizer S
Distributed worldwide by:
SANUSLIFE INTERNATIONAL GmbH
Luigi Negrelli 13/C, 39100 Bolzano (I)
Phone: +39 0471 979998
www.sanuslife.com - info@sanuslife.com
ACID
PU
ALK
Filter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECAIA S and is the answer not in the manual?

Questions and answers

Summary of Contents for SANUSLIFE ECAIA S

  • Page 1 Additional faucet for ECAIA ionizer S Additional operating instructions to be used in combination with User manual for the ECAIA ionizer S Distributed worldwide by: SANUSLIFE INTERNATIONAL GmbH Luigi Negrelli 13/C, 39100 Bolzano (I) Phone: +39 0471 979998 www.sanuslife.com - info@sanuslife.com...
  • Page 2: C Scope Of Delivery Ecaia Ionizer S Faucet

    Scope of delivery ECAIA ionizer S faucet 1/4" 12 x 1/4" 5/16" 4 x 5/16" 3x8 mm 4x16 mm ECAIA ionizer S faucet - Display...
  • Page 3: E Installation Diagram (4.1)

    Installation diagram Point 4.1, page 6 Installation diagram Point 4.2, page 7 Ø 35 mm Maximum distance between faucet and ionizer: 1.5 m 5/16" 1/4" 5/16" 5/16" - 1/4" 5/16" - 1/4" 1/4" - 1/4" 1/4"...
  • Page 4: Table Of Contents

    ECAIA ionizer S faucet Table of contents Scope of delivery ECAIA ionizer S faucet ..............2 ECAIA ionizer S faucet - Display ................... 2 Installation diagram (4.1) ....................3 Installation diagram (4.2) ....................3 Table of contents ......................4 Scope of delivery ECAIA ionizer S faucet ..............4 ECAIA ionizer S faucet - Display ..................
  • Page 5: Ecaia Ionizer S Faucet - Display

    ECAIA ionizer S faucet - Display Compare table D (p. 2). Control cable – transmits signal to the ECAIA ionizer S+ Quick release fastener 5/16" – connection for alkaline water outlet Quick release fastener 1/4" – connection for acidic water outlet Display (ECAIA ionizer S faucet) Power button –...
  • Page 6: Installation Of Ecaia Ionizer S+ And Ecaia Ionizer S Faucet

    Installation of ECAIA ionizer S+ and ECAIA ionizer S faucet Permanent connection to the angle valve (ECAIA ionizer S+; appliance in below counter position) Compare table E (page 3). The ECAIA ionizer S+ can be permanently connected to the angle valve under the sink, as described under point “1.4 - Permanent connection to the angle valve (appli- ance in above-counter position)”.
  • Page 7: Installation Of The Additional Ecaia Ionizer S Faucet

    quick-release fastener opening of the water inlet (B-11) on the bottom of the ECAIA ionizer S. Finally, fix the 5 1/4” safety pins (C-6) in place. Afterwards, connect the cable of the solenoid valve (C-12) to the cable plug-in connector on the bottom of the ECAIA ionizer S. 4.
  • Page 8 3. Choose a location next to the sink for the 2-way fitting (C-1) so that it can be operat- ed professionally without interfering with the work around the sink. The location you choose should be approx. 4 cm (1.5") from the edge of the sink and approx. 30 cm (11"-12") from the faucet.
  • Page 9: Reprogramming The Ecaia Ionizer S Control To Ecaia Ionizer S

    5/16" - 1/4" 1/4" - 1/4" 1/4" The ECAIA ionizer S can be placed in a lower cabinet or mounted to the wall. To do this, please follow the instructions under point “1.6 - ECAIA ionizer S Wall Mounting” in the complete user manual (long version) for the ECAIA ionizer S.
  • Page 10 3. Press and hold the “acidic level 1” (B-25) button on the ECAIA ionizer S until “F-1” is displayed. 4. Press and hold on the ECAIA ionizer S the button combination “alkaline level 5” (B-24) and “PURIFY” (B-26) at the same time until the display (B-2) switches off. This saves the setting.
  • Page 11: Reprogramming The Ecaia Ionizer S+ Control To Ecaia Ionizer S

    Reprogramming the ECAIA ionizer S+ control to ECAIA ionizer S If you wish to use the ECAIA ionizer S+ again without the ECAIA ionizer S faucet, you can reprogram the ECAIA ionizer S controls as described below: 1. On the ECAIA ionizer S faucet, press and hold the “Power (D-D1)” and “Alkaline lev- els (ALK) (D-D2)”...
  • Page 12: Operation Of Ecaia Ionizer S Faucet

    6. Plug the power cable of the ECAIA ionizer S+ into the socket. You can now use the ECAIA ionizer S+ again using the control panel (B-1) on the ECAIA ionizer S+. Operation of ECAIA ionizer S faucet The device can be switched on and off using the power button (D-D1). The button “ALK”...
  • Page 14 ACID Filter ② ① Additional faucet for ECAIA ionizer S Distributed worldwide by: SANUSLIFE INTERNATIONAL GmbH Luigi Negrelli 13/C, 39100 Bolzano (I) Phone: +39 0471 979998 www.sanuslife.com - info@sanuslife.com...