ENGLISH
USES
Grade 2 and 3 Ankle Sprains, Stable Fractures, Post-Operative Use, Trauma,
Rehabilitation, and Hot/Cold Therapy
CAUTION
DO NOT REMOVE WALKER UNLESS INSTRUCTED BY PHYSICIAN.
1. This product has been designed and tested based on single patient usage and is not
recommended for multiple patient usage.
2. If skin irritations of any kind develop, consult medical professional immediately.
3. Be sure the patient performs circulation checks. If a loss of circulation is felt, or if the
walker feels too tight, release contact closure straps and adjust to a comfortable level.
If discomfort continues, the patient should contact their medical professional
immediately.
4. Caution should be used if prescribed for patients with diabetes, vascular deficiencies,
and neuropathies.
5. Do not remove the inner foam pads which are adhered to the plastic walker boot.
PHOTO CAPTIONS
A. Pull tabs
B. Adjustable air pump
C. Walker struts
D. Adjustable pneumatic softgood
E. Wide rocker bottom base
F. Adjustable contact closure straps
G. Foam pads
FITTING INSTRUCTIONS
1. Remove softgood by opening contact closure straps and lifting out of brace. Do not
remove pull tabs at this time.
2. Place lower leg and foot into softgood. Close softgood snugly over leg.
3. Insert foot into brace by gently spreading uprights. Do not remove pull tabs at this
time.
4. Ensure struts are centered over the ankle bone (malleoli). The lower leg should be
kept at a 90° angle with the foot.
5. Remove pull tabs located in between struts and softgood. This allows the softgood to
be secured into position.
6. To accommodate for rubbing or spacing, additional foam pads may be placed inside
the softgood, in between the softgood and plastic, or under straps for additional
comfort.
7. Secure contact closure straps, starting at the toes and working upward. For best fit,
secure straps in the correct order.
Strap adjustments may be necessary as foot, ankle and leg swelling patterns change.
8. Inflate air chamber by turning knob clockwise until secure and pressing and releasing
the air bulb repeatedly.
Continue until softgood feels stable and is cushioning the lower leg. Do not over
inflate.
9. Air can be released from air chamber by turning the inflation/deflation knob
counterclockwise. To re-inflate, repeat step 8.
10. When prescribed by physician, remove leg from product by releasing contact closure
straps and opening softgood.
Pull foot and leg forward and out, leaving softgood inside the brace. If softgood is
removed, follow Steps 1 through 7 to reapply.
WASHING INSTRUCTIONS
1. This product can be washed at any time by hand using a mild detergent and cold
5
Need help?
Do you have a question about the Equalizer Air Walker and is the answer not in the manual?
Questions and answers