4. TROUBLESHOOTING
4-2-8) When the Compressor is not working (INVERTER PBA)
When the inverter PBA LED
is ON, it indicates that
the compressor does
operate normally
Refer to the TEST
Function in this manual
Forced Operation signal sound
should be checked
0~800Hz 50% Duty
Signal Output
Check the wire harness
Replace the MAIN PBA
Replace INVERTER PBA
Start
10 minutes have
passed since COMP
was off
Yes
When Forced
Operation mode is activated,
COMP operates
Yes
Yes
COMP operation
No
Signal(CN201 ②↔③) is High(about DC
2-2.5V or AC 0~5.0V)
Yes
No
Is DC 16V applied to
ZD501?
Yes
CN101/CN102 Connector
is Good
Yes
COMP ASS'Y is Good
Yes
NORMAL (Recheck)
☞ SMPS Primary Voltage checking(+16V) : REG1(+5V)
Terminal(Input and GND) : DC16V±1.6V
Terminal(Output and GND) : DC5V±0.2V
No
Check in 10 minutes
No
Temperature Sensor is
normal?
Temperature
sensing part of MAIN PBA is
Good
Replace MAIN PBA or
Repair the connection
No
Check the COMP wire
Check the Compressor
Check AC Power wire
No
Replace COMP ASS'Y
71
No
Yes
Replace the Sensor
No
Repair the sensing part or
Yes
Replace MAIN PBA