This manual is intended to meet the Manufacturer’s Instructions as required by the Canadian Standards Association (CSA) Z259 and should be used as part of an employee training program. CMSRD08 Rev A FallTech 1306 S. Alameda Street Compton, CA 90221, USA Tel: 800-719-4619 Fax: 323-752-5613 022420...
Appendix A ......................... For purposes of this manual, the FallTech® Contractor Leading Edge SRL-LE in all iterations may be referred to collectively as the Contractor SRL-LE , the SRD Leading Edge (SRD-LE), the self-retracting device, the equipment, the device, the product, or the unit.
Do not alter or intentionally misuse this equipment. • Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. • Do not connect rebar hooks, large carabiners, or large snap hooks to the FBH dorsal D-rings as this may cause a roll-out condition and/or unintentional disengagement.
Description The FallTech® Contractor Leading Edge SRL-LE is a self-retracting device for those working at height and whom may be subject to Leading Edge fall hazards; see Figure 11 for typical extreme sharp edges. The SRD discussed in this manual may be attached to an overhead anchorage, i.e., from directly over the user’s head, to as low as the level of the user’s FBH dorsal D-ring.
Application 3.1 Purpose: The FallTech Contractor Leading Edge SRL-LE is designed to be used as a component in a Personal Fall Arrest System (PFAS), to provide a combination of worker mobility and fall protection as required for inspection work, general construction, maintenance work, oil production, confined space work, etc.
Page 6
4.4 Making Connections: Only use self-locking connectors with this equipment. Only use connectors that are suitable to each application. Ensure all connections are compatible in size, shape, and strength. Do not use equipment that is not compatible, see Figure 3. Visually ensure all connectors are fully closed and locked.
WARNING Do not alter or intentionally misuse this equipment. Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. All components or subsystems used with the SRD discussed in this manual must be in compliance with CSA Z259.
Page 8
5.2 Calculating SRL-LE MRFC 5.2.1 SRL-LE in Overhead, Non-Leading Edge Anchorage Application The Leading Edge SRD may be used may be used as a standard SRD in an overhead condition, in which the SRD is installed anywhere in the allowable attachment area, which ranges from directly above the user to level with the FBH D-ring, as shown in Figure 4. The overhead condition MRFC has six metrics, labeled A –...
Page 9
Chart 1: Additional Fall Clearance Due to Swing Fall (meters): Overhead, Non-Leading Edge Condition 15.2 13.7 12.2 10.7 Dorsal 10.4 11.0 D-Ring 10.4 11.0 X-Axis: Lateral Work Zone (m) Using Chart 1 to Find Additional Fall Clearance: Overhead, Non-Leading Edge 0.6 m (2 ft) increments along the X-Axis represent the 1.5 m (5 ft) increments up the Y-Axis represent the SRD distance the user is working away from being directly...
Page 10
NOT account for swing fall. If a swing fall condition exists, use Chart 2 to determine “G”, the additional fall clearance needed. G+F=H is the total fall clearance required. Figure 6 - Calculating Minimum Required Fall Clearance SRL-LE 5’ Minimum Setback from Leading Edge and 5’ Below Dorsal D-Ring Anchorage 2.6 m...
Page 11
Swing Fall with 1.5 m (5 ft) Setback: A swing fall condition is created when the user travels laterally from directly in front of or below the anchorage, as shown in Figure 7. For each foot of work zone expansion, the risk of severe injury or death from a swing fall increases. This increased risk requires additional MRFC distance, up to a maximum of 1.2 m (4 ft) of added clearance.
Page 12
Chart 2: Additional Fall Clearance Due to Swing Fall (meters) with Leading Edge Conditions for 1.5 m (5 ft) Setback from Leading Edge with Foot Level Anchorage 15.2 13.7 12.2 10.7 Dorsal D-Ring -1.5 10.4 11.0 X-Axis: Lateral Work Zone (m) Using Chart 2 to Find Additional Fall Clearance: Leading Edge Conditions 0.6 m (2 ft) increments along the X-Axis represent the 1.5 m (5 ft) increments up the Y-Axis represent the SRD...
Page 13
NOT account for swing fall. If a swing fall condition exists, use Chart 3 to determine “G”, the additional fall clearance needed. G+F=H is the total fall clearance required. Figure 8 - Calculating Minimum Required Fall Clearance SRL-LE 0’ Minimum Setback from Leading Edge and 5’ below Dorsal D-Ring Anchorage 3.8 m...
Page 14
Swing Fall with 0’ Setback: A swing fall condition with 0’ setback in Figure 9. For each foot of work zone expansion, the risk of severe injury or death from a swing fall increases. This increased risk requires additional MRFC distance, up to a maximum of 4’ of added clearance.
Page 15
Chart 3: Additional Fall Clearance Due to Swing Fall (meters) with Leading Edge Conditions for 0 m (0 ft) Setback from Leading Edge with Foot Level Anchorage 15.2 13.7 12.2 10.7 Dorsal 10.4 11.0 D-Ring -1.5 10.4 11.0 10.4 11.0 X-Axis: Lateral Work Zone (m) Using Chart 3 to Find Additional Fall Clearance: Leading Edge Conditions 0.6 m (2 ft) increments along the X-Axis represent the...
Page 16
5.3 Angle of Redirection: The angle of redirection is the angle of the lifeline over an edge during a fall event. Install the SRD so that the angle of the two parts of the lifeline are at least 90°, or more, but never less, as shown in Figure 10. The lifeline must never rise up to the edge as it may bend the lifeline in too small a radius and/or severely abrade, or otherwise compromise, the lifeline.
Page 17
5.5 Incorrect Use: Additional factors to avoid, shown in Figure 12: Do not allow the lifeline to drape over and edge during normal work as this may abrade, damage, or otherwise compromise the lifeline. Do not attach the anchor on one side of an opening and work on the other side, as this creates multiple possible leading edges and potential swing fall hazards.
Page 18
SRD functionality, and may result in serious injury or death. If additional lifeline is accidentally pulled from the SRD without a fall event, remove the SRD from service and contact FallTech for options A red band is further up the lifeline. The red band, also shown in Figure 14, indicates the reserve portion of the lifeline has been breached.
5.8 After A Fall: A fall event over an edge may require special rescue equipment and measures. Ensure a written rescue plan, method and system is in place and readily available to all users for rapid response. Ensure all users are trained in rescue procedures. If a fall event occurs, remove it from service, and store it separately.
Page 20
7.2 Inspection Frequency: CSA Z259.2.2 requires an inspection by a competent person at least once a year by a person other than the user of the system. Inspection Requirements for Self-Retracting Devices Competent Worker Person Product Example Conditions Type of Use Application Examples Inspection Inspection...
Page 21
Inspection Document: Record inspection results on the Inspection Record provided below or on a similar document. Inspection Record Model #:_________________________ Serial #:_________________________ Date of Manufacture:_________________________ INSPECTION INSPECTOR COMMENTS PASS/FAIL CORRECTIVE ACTION NEEDED APPROVED BY DATE CMSRD08 Rev A 022420...
Labels The labels must be present and legible. CMSRD08 Rev A 022420...
Page 23
15.1 kN (3400 lbs.) 22.2 kN (5,000 lbs) Min 16 kN (3,600 lbs) Gate Z259.2.2-17 Strength C727650LE 15.2 m (50 ft) Table 1B: FallTech Leading Edge SRL-LE Performance Attributes Part #s and Conditions Typical FallTech Performance CSA Performance Requirements Maximum Average Anchorage...
Page 25
Le présent manuel est conçu pour répondre aux consignes du fabricant telles qu'exigées par l'Association canadienne de nor- malisation (CSA) Z259 et devrait être utilisé dans le cadre d'un programme de formation des employés. CMSRD08 Rév A FallTech 1306, rue Alameda, Compton, CA 90221, É.-U. Téléphone: 800 719-4619 Télécopieur: 323 752-5613 022420...
Page 26
Annexe A ........................Pour les besoins de ce manuel, le bord d'attaque FallTech® SRL-BA dans toutes les itérations peut être désigné collectivement comme l'entrepreneur SRL-BA, le bord d'attaque DAR (DAR-BA), le dispositif autorétractable, l'équipement, le dispositif, le produit ou l'unité.
• N'altérez pas l'équipement intentionnellement et utilisez-le correctement. • Consultez FallTech lorsque vous utilisez cet équipement en combinaison avec des composants ou sous-systèmes autres que ceux décrits dans ce manuel. • Ne pas connecter d'émerillon ou de gros mousqueton aux anneaux dorsaux en D du harnais corporel complet, car cela pourrait provoquer une condition de décrochage ou un désengagement involontaire.
Description L'entrepreneur de bord d'attaque de FallTech® SRL-BA est un dispositif auto-rétractable pour les personnes qui travaillent en hauteur et qui peuvent être exposées à des risques de chute sur le bord d'attaque; voir la figure 11 pour les bords coupants extrêmes typiques.
CSA Z259.2.2-2017. La CSA exige que tous les DAR soient classés selon leur type respectif et comme suit : classe SRL, classe SRL-R, classe SRL-LE ou classe SRL-BA-R. Le dispositif auto-rétractable entrepreneur SRL-BAR dans ce manuel est de classe SRL-LE.
Page 30
4.4 Obtenir des connexions: n'utilisez que des connecteurs autobloquants avec cet équipement. N'utilisez que des connecteurs adaptés à chaque application. S'assurer que toutes les connexions soient compatibles en matière de taille, de forme et de résistance. N'utilisez pas d'équipement qui n'est pas compatible, voir la figure 3. Assurez-vous visuellement que tous les connecteurs sont complètement fermés et verrouillés.
AVERTISSEMENT Ne pas modifier ou briser cet équipement de façon intentionnelle. Consulter FallTech lors de l'utilisation de cet équipement en combinaison avec des composants ou sous-systèmes autres que ceux décrits dans ce manuel. Tous les composants ou les sous-systèmes utilisés avec le DAR dont il est question dans ce manuel doivent être conformes à...
Page 32
5.2 Calcul du SRL-BA de la DMC 5.2.1 SRL-BA dans l'application d'ancrage aérien sans bord d'attaque Le bord d'attaque du DAR peut être utilisé comme un DAR standard dans un état en hauteur, dans lequel le DAR est installé n'importe où...
Page 33
Charte 1: dégagement additionnel dû à la chute par balancement (mètres) : au-dessus, condition sans bord d'attaque 15,2 13,7 12,2 10,7 Anneau 10,4 11,0 dorsal en D 10,4 11,0 Axe X: Zone de travail latéral (m) Utiliser la charte 1 pour trouver d'autres dégagements: au-dessus, sans bord d'attaque Les incréments de 0,6 m (2 pi) le long de l'axe X Les incréments de 1,5 m (5 pi) vers le haut de l'axe Y représentent la distance à...
Page 34
5.2.2 1,5 m (5 pi) de recul par rapport au bord d'attaque et 1,5 m (5 pi) sous l'ancrage dorsal de l'anneau en D Le point d'ancrage étant en retrait et sous l'anneau en D, comme le montre la figure 6, il y a sept variables à prendre en compte lors du calcul du DMC.
Page 35
Chute basculement avec une marge de recul de 1,5 m (5 pi): une condition de chute par basculement est créée lorsque l'utilisateur se déplace latéralement à partir de l'avant ou de l'arrière de l'ancrage, tel qu'illustré à la figure 7. Pour chaque pied d'expansion de la zone de travail, le risque de blessures graves ou de décès à...
Page 36
Tableau 2: dégagement additionnel en cas de chute due à une chute par basculement (mètres) avec conditions de bord d'attaque pour 1,5 m (5 pi) de recul par rapport au bord d'attaque lors d'un ancrage au niveau du pied 15,2 13,7 12,2 10,7...
Page 37
5.2.3 0 pi de recul par rapport au bord d'attaque et 5 pi sous l'ancrage de l'anneau dorsal en D L'ancrage étant installé à zéro en retrait et sous l'anneau en D, comme le montre la figure 8, il y a huit paramètres à prendre en compte dans le calcul du DMC.
Page 38
Chute par basculement avec 0 pi de recul: une condition de chute par basculement avec une marge de recul de 0 pi à la figure 9. Pour chaque pied d'expansion de la zone de travail, le risque de blessures graves ou de décès à la suite d'une chute par basculement augmente.
Page 39
Tableau 3 : dégagement de chute supplémentaire dû à une chute par basculement (mètres) avec conditions de bord d'attaque de 0 m (0 pi) de recul par rapport au bord d'attaque avec ancrage au niveau du pied 15,2 13,7 12,2 10,7 neau 10,4...
Page 40
5.3 Angle de redirection: l'angle de redirection est l'angle de la ligne de vie au-dessus d'un bord pendant une situation de chute. Installez le DAR de façon à ce que l'angle des deux parties de la ligne de vie soit d'au moins 90°, ou plus, mais jamais moins, comme illustré à la fig- ure 10.
Page 41
5.5 Utilisation incorrecte: facteurs supplémentaires à éviter, voir la figure 12: Ne laissez pas la ligne de vie se recouvrir et se tordre pendant le travail, car cela pourrait l'abîmer, l'endommager ou la compromettre. Ne pas fixer l'ancrage d'un côté d'une ouverture et travailler de l'autre côté, car cela crée de multiples bords d'attaque possibles et des risques potentiels de chute.
Page 42
Si une ligne de vie supplémentaire est accidentellement retirée du DAR sans qu'il y ait eu une chute, retirer celui-ci du service et contacter FallTech pour les options. Une bande rouge est plus haut sur la ligne de vie. La bande rouge, également illustrée à la figure 14, indique que la portion de réserve de la ligne de vie a été...
5.8 Après une chute: une chute au-dessus d'un bord peut nécessiter un équipement et des mesures de sauvetage spéciaux. Veiller à ce qu'un plan, une méthode et un système de sauvetage écrits soient en place et facilement accessibles à tous les utilisateurs pour une intervention rapide.
Page 44
7.2 Fréquence d'inspection: la norme CSA Z259.2.2 exige une inspection par une personne compétente au moins une fois par année par une personne autre que l'utilisateur du système. Exigences d'inspection pour les dispositifs d'autorétraction Fréquence de Fréquence de Exemples de Fréquence de Type l'inspection...
Page 45
7.5 Inspection du document:Inscrire les résultats de l'inspection dans le registre d'inspection fourni ci-dessous ou dans un document semblable. Registre d'inspection № de modèle :________________________ № de série :________________________ Date de fabrication :_________________________ DATE D'IN- SUCCÈS/ MESURES CORRECTIVES NÉCES- INSPECTEUR COMMENTAIRES APPROUVÉ...
16 kN (3 600 lb) Z259,2,2-17 Résistance de la vanne C727650LE 15,2 m (50 pi) Tableau 1B : caractéristiques de performance du SRL-BA bord d'attaque de FallTech Numéro des pièces et conditions Performance typique FallTech Exigences de rendement de CSA Condition...