First Alert UL539 User Manual
First Alert UL539 User Manual

First Alert UL539 User Manual

120v ac powered 135f fixed temperature heat alarm user's manual

Advertisement

Quick Links

120V AC POWERED
135ºF FIXED TEMPERATURE HEAT ALARM
~
120V AC
60 Hz
0.05 Amps
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information
about your Heat Alarm's operation. If you are installing
this Heat Alarm for use by others, you must leave this
manual-or a copy of it-with the end user.
M08-0193-001 P 08/08 Printed in Mexico

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Heat Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How This Heat Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
How To Install This Heat Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If You Suspect a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If This Heat Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Responding To An Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Locations For Heat Alarms . . . . . . . . . . . . . . . . . . . . . .4-5
Locations To Avoid For Heat Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Limitations of Heat Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
© 2008 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005
www.brkelectronics.com • www.firstalert.com

INTRODUCTION

Thank you for choosing First Alert
purchased a state-of-the-art Heat Alarm designed to provide you with early
warning of increased temperatures that may be the result a fire.
Key features include:
135º F Fixed Temperature Sensor-Programmed to alarm when temperature
reaches 135º F.
Interconnectable-Can be interconnected with First Alert
CO, and Heat Alarms.
USER'S MANUAL
LISTED TO
UL 539
STANDARD
Model
HD6135F
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
®
for your Heat Alarm needs. You have
®
and BRK

FIRE SAFETY TIPS

Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters away
from children; 3) Store flammable materials in proper containers; 4) Keep
electrical appliances in good condition and don't overload electrical circuits;
5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-
free; 6) Never leave anything cooking on the stove unattended; 7) Keep
portable heaters and open flames, like candles, away from flammable
materials; 8) Don't let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they
are not working properly. Heat and Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fire extinguisher on every floor,
and an additional one in the kitchen. Have fire escape ladders or other reliable
means of escape from an upper floor in case stairs are blocked.

BEFORE YOU INSTALL THIS HEAT ALARM

IMPORTANT! Read "Recommended Locations for Heat Alarms" and
"Locations to Avoid for Heat Alarms" before beginning. This unit monitors
the air, and when heat reaches its sensing chamber, it alarms. It can give
you more time to escape before fire spreads. This unit can ONLY give an
early warning of developing fires if it is installed, maintained and located
where heat can reach it, and where all residents can hear it, as described in
this manual. This unit will not sense gas, smoke, or flame. It cannot prevent
or extinguish fires.
Know Where To Install Your Heat Alarms
See "Recommended Locations For Heat Alarms" and "Locations To Avoid
For Heat Alarms" for details.
Know What Heat Alarms Can and Can't Do
A Heat Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once heat reaches the sensor.
See "Limitations of Heat Alarms" for details.
Check Your Local Building Codes
This Heat Alarm is designed to be used in a typical single-family home. It
alone will not meet requirements for boarding houses, apartment buildings,
hotels or motels. See "Special Compliance Considerations" for details.
• This device is not intended to alert hearing impaired residents.
Smoke Alarms specifically designed for the hearing impaired,
which feature devices like flashing strobe lights, are available
to alert the hearing impaired in case of fire.
• Installation of this Heat Alarm must conform to the electrical
codes in your area; Articles 210 and 300.3 (B) of the National
Electrical Code (NFPA 70), NFPA 72, NFPA 101; SBC (SBCCI);
NBC (BOCA); OTFDC (CABO), and any other local or building
codes that may apply. Wiring and installation must be performed
by a licensed electrician. Failure to follow these guidelines may
result in injury or property damage.
• This Heat Alarm is not a Smoke Alarm. This unit is not suitable
protection when used alone. Do not use this unit as the only
means of fire detection in a home. This unit is intended for use
as a supplement to Smoke Alarms.
• This Heat Alarm must have AC to operate. If AC power fails, the
alarm cannot operate.
• This unit must be powered by a 24-hour, 120VAC 60Hz circuit.
Be sure the circuit cannot be turned off by a switch, dimmer, or
ground fault circuit interrupter. Failure to connect this unit to a
24-hour circuit and keeping fresh batteries installed, may prevent
it from providing constant protection.
• Never disconnect the power from an AC powered unit to stop an
unwanted alarm. Doing so will disable the unit and remove your
protection. In the case of a true unwanted alarm, press the Test
button or fan the heat away from the unit. The alarm will reset
automatically when it returns to normal operation.
• NEVER ignore any alarm. Read "If Your Heat Alarm Sounds" for
more information on how to respond to an alarm. Failure to
respond can result in injury or death.
®
Smoke,
• Test this Heat Alarm once a week. If it ever fails to test correctly,
have it replaced immediately! If the Alarm is not working properly,
it cannot alert you to a problem.
• Connect this Heat Alarm ONLY to other compatible units.
See "Special Requirements for Interconnected Heat Alarms" for
details. Do not connect it to any other type of alarm or auxiliary
device. Connecting anything else to this unit may damage it or
prevent it from operating properly.
• DO NOT stand too close to the unit when the alarm is sounding.
It is loud to alert you in an emergency. Exposure to the horn at
close range may harm your hearing. When testing the unit, step
back when the horn starts sounding.
• Do not paint over the Heat Alarm. Paint may clog the openings to
the sensor and prevent the Heat Alarm from operating properly.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UL539 and is the answer not in the manual?

Questions and answers

Summary of Contents for First Alert UL539

  • Page 1: Table Of Contents

    Failure to follow these guidelines may result in injury or property damage. • This Heat Alarm is not a Smoke Alarm. This unit is not suitable protection when used alone. Do not use this unit as the only means of fire detection in a home.
  • Page 2: How This Heat Alarm Works

    This Heat Alarm monitors the air and when heat reaches the sensor, it alarms. The unit will alarm when the temperature reaches a fixed 135º F (57º C). Heat Alarms are intended for use as supplemental safety devices with Smoke Alarms. Heat Alarms are designed for use in areas where Smoke Alarms cannot be installed due to temperature and environmental conditions, as in unheated garages and crawl spaces.
  • Page 3: Weekly Testing

    The basic installation of this Heat Alarm is the similar whether you want to install one Heat Alarm, or interconnect more than one Heat Alarm. If you are interconnecting more than one Heat Alarm, you MUST read “Special Requirements for Interconnected Heat Alarms” below before you begin installation.
  • Page 4: If You Suspect A Problem

    IF YOU SUSPECT A PROBLEM Heat Alarms may not operate properly because of a build-up of dirt, dust or grease on the Heat Alarm cover, or installation in an improper location. Clean the Heat Alarm as described in “Regular Maintenance,” then test the Heat Alarm again.
  • Page 5: Locations To Avoid For Heat Alarms

    California State Fire Marshal (CSFM) Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A Smoke Alarm installed in each separate sleeping area (in the vicinity, but outside bedrooms),...
  • Page 6: Limitations Of Heat Alarms

    That is why recommended minimum protection is at least one Smoke Alarm on every level of your home and Heat Alarms in any areas not suitable for Smoke Alarms. Even with a unit on every floor, stand-alone units may not provide as much protection as interconnected units, especially if the fire starts in a remote area.

This manual is also suitable for:

Hd6135f

Table of Contents