Changing A Particular Option; 02 Series Installation Option - Samsung MIM-E03CN Installation Manual

Air to water heat pump control kit
Hide thumbs Also See for MIM-E03CN:
Table of Contents

Advertisement

Installation option setting

Changing a particular option

You can change each digit of set option.
Option
SEG1
Explanation
PAGE
Remote
Controller
Display
Indication Details
Indication and
Details
0
• When changing a digit of an control kit address setting option, set the SEG3 as 'A' .
• When changing a digit of control kit installation option, set the SEG3 as '2' .
NOTE
Ex) When setting the 'central controller' into disuse status.
Option
Explanation
Indication

❋ 02 Series installation option

Classification
Use central controller (Default)
Disuse central controller
❋ 01 Series Production Option (Factory default)
40
SEG2
The option mode you
MODE
Indication
Details
Indication
D
Option mode
SEG1
SEG2
PAGE
MODE
0
D
Mode 1
MIM-E03CN
SEG3
SEG4
The tens' digit of an
option SEG you will
want to change
change
Details
Indication
Tens' digit
1~6
of SEG
SEG3
The tens' digit
The option
of an option
mode you want
SEG you will
to change
2
SEG5
The unit digit of an
option SEG you will
change
Details
Indication
Details
Unit digit
0~9
0~9
of SEG
SEG4
SEG5
The unit digit
of an option
SEG you will
change
change
0
5
SEG1~24
020010 100000 200000 300000
020000 100000 200000 300000
SEG1~24
012300 100000 200000 300000
SEG6
The changed value
Indication
Details
The changed
0~F
value
SEG6
The changed
value
0

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading