DIAGNOSTICS and TROUBLESHOOTING (Cont.)
Service Test Cycle Chart – Condenser Dryer Output Status
Step
Test/Tested
Components
No.
S1
Service Test
S2
Pump
S5
CW Motor
S7
CCW Motor
S11
Water Level Sensor
Exit Service Diagnostic
EXIT
Mode/Service Test Cycle
Displayed Code
Explanation and Recommended Procedure
F1E1
Error Code is displayed when the ACU detects any of the following errors:
To troubleshoot:
F1E2
Error Code indicates a motor failure of one of the possibilities:
To troubleshoot:
F3E1
Indicates a problem in the Front Thermistor circuit.
To troubleshoot:
F3E3
Indicates a problem in the Hot thermistor circuit.
To troubleshoot:
2-4
n
Whirlpool
24" Compact Condensing Dryer
®
For Service Technician Use Only
Master Relays
Drain Pump Test
Clockwise Motor Test
Counterclockwise Motor Test
Water Level Sensor Test
PASS/FAIL/End of Cycle
Faults and Error Codes
•
A feedback signal is different than what is expected.
•
An input signal is Out of Range.
•
The voltage bus on the ACU is bad.
1. Attempt to perform Service Test Cycle on
diagnose a door switch problem.
2. If the cycle starts, perform
as needed, try to run a cycle.
3. If the heater and the door switch diagnostics did not resolve the failure, perform
a possible moisture sensor circuit issue. Replace parts as needed, and try to run a cycle.
4. If fault code is still present after all diagnostics, replace ACU.
•
Over Current
•
DC Bus Over/Under Voltage
•
Locked Rotor
•
Motor Inverter Over Temperature
•
Drum Motor Overheating
•
Drum Motor MCU Failure
•
Phase on Drum Motor Lost
•
Other Drum Motor Failures
•
Perform
Test #1
to diagnose if the ACU is at fault.
•
Perform
Test #3
to diagnose the motor circuit to verify the failure of the motor.
•
Perform
Test #4b
to diagnose the Thermostat Circuit.
•
Perform
Test #4b
to diagnose the Thermostat Circuit.
Heater
Description
page
2-4. If the routine is unable to start, perform
Test
#4, and to diagnose a possible heater system problem. Replace parts
Output Status
Heater
Motor
1
2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
CW
OFF
OFF
CCW
OFF
OFF
OFF
Pump
OFF
ON
OFF
OFF
ON
Test #7
to
Test
#5, to diagnose
Need help?
Do you have a question about the W11440958 and is the answer not in the manual?