flame. Sources of these fires may include cigarettes burning in couches or bedding. For maximum protection, use both types of smoke alarms on each level of your home. Model 4120B 4120SB AC Powered Ionization Smoke Alarm with Battery Back-up Cat. 4120B Input: 120V AC, 60Hz, 0.5A M06-2016-007 06/00...
Installing Smoke Alarms in Single-Family And Multi-Family Residences The National Fire Protection Association (NFPA), recommends one smoke alarm on every floor, in every sleeping area, and in every bedroom. In new construction, the smoke alarms must be AC powered and interconnected. See “Agency Placement Recommendations”...
Page 4
In new construction a smoke alarm shall also be installed in each sleeping room. Chapter 2 also reads as follows: 2-2.2.1: In new construction, where more than one smoke alarm is required by 2-2.1, alarms shall be so arranged that...
• In very dusty, dirty, or greasy areas. Do not install a smoke alarm directly over the stove or range. Clean a laundry room unit frequently to keep it free of dust or lint. •...
Page 6
“dead air” spaces. On a peaked, gabled, or cathedral ceiling, install the first smoke alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally. Additional smoke alarms may be required depending on the length, angle, etc.
Important! Read Before You Install This Smoke Alarm Read “Where To Install Smoke Alarms” and “Where Not To Install Smoke Alarms” before beginning. This unit monitors the air, and when smoke reaches its sensing chamber, it alarms. It can give you more time to escape before fire spreads.
NOTE: When power is applied, unit(s) may alarm momentarily. *When any smoke alarm in an interconnected series triggers an alarm, its red LED will flash rapidly. The red LEDs will remain OFF on any remaining alarms in the series. This feature helps responders identify which unit(s) triggered the alarm.
These smoke alarms have two separate locking features: one to lock the battery compartment, and the other to lock the smoke alarm to the mounting bracket. You can choose to use either feature independently, or use them both.
Page 10
WARNING! Always discharge the branch circuit before servicing an AC or AC/DC smoke alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from smoke alarms with battery back-up.
Page 11
2. Insert the locking pin into the lock located on the pivoting hinge of the battery door. 3. When you attach the smoke alarm to the mounting bracket, the locking pin’s head will fit into a notch on the bracket.
How To Install This Smoke Alarm This unit is designed to be mounted on any standard wiring junction box up to a 4-inch diagonal size, on either the ceiling or wall. Read “Where to Install” and “Where Not To Install” smoke alarms before you begin installation.
4. Position the base of the alarm over the mounting bracket and turn. The alarm can be positioned over the bracket every 60°. Turn the smoke alarm clockwise (right) until the unit is in place. 5. If you are only installing one unit, restore power to the junction box.
Interconnected units will only work if they are wired to compatible units and all requirements are met. This unit is designed to be compatible with: ® BRK Electronics Smoke Alarms 100S, 2002RAC, 4120B, 4120SB, 4919, 5919, 5919TH, 86RAC; ® BRK Electronics Heat Alarm HD6135F; and ® First Alert Smoke Alarms SA4120B, SA4121B, SA4919B, SA86B, SA100B.
Page 15
6. Make sure each unit is receiving AC power. Under normal operation, the green power indicator light will shine continuously. 7. Test each smoke alarm. Press and hold the test button until the unit alarms. When testing a series of interconnected units you must test each unit individually.
Underwriters Laboratories, Inc. (UL). If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards, and use it only as directed.
1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the smoke alarm and the environment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit.
Cat. 4120SB Only— Using The Silence Feature The silence feature on this unit can temporarily quiet an unwanted alarm for several minutes. CAUTION! The silence feature does not disable the unit—it makes it temporarily less sensitive to smoke. For your safety, if smoke around the unit is dense enough to suggest a potentially dangerous situation, the unit will stay in alarm or may re-alarm quickly.
Teach them to stay close to the floor and crawl if necessary. Install at least one smoke alarm on every level of your dwelling and/or dwelling unit, in every bedroom, and in every sleeping area. Keep alarms clean, and test them weekly.
Needs Service CAUTION! Always discharge the branch circuit before servicing an AC or AC/DC smoke alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from smoke alarms with battery back-up. Finally, press and hold the test button for 5- 10 seconds to discharge the branch circuit.
• Check if you accidentally pushed the test button. You experience frequent • Check the location of the smoke alarm. The smoke alarm may be too unwanted alarms (like in close to a kitchen, cooking appliance, or steamy bathroom. (See “Where response to cooking To Install Smoke Alarms.”)
Special Compliance Considerations This unit alone is not a suitable substitute for complete fire detection systems in places housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, nursing homes, day care facilities, or group homes of any kind—even if they were once single- family homes.
Smoke alarms have a limited life.The unit should be replaced immediately if it is not operating properly. You should always replace a smoke alarm after 10 years from date of manufacture. See back of smoke alarm for manufacture date.
10-YEAR LIMITED WARRANTY Coverage: BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship under normal use for a period of ten years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc. will replace any defective smoke alarm without charge.