Commissioning | Automax 100 | Extension module TS-AC E2-M3-1X
Bosch Rexroth AG | 05.2021 | DOK-SUPPL*-TS-AC E2-M3-ITRS-EN-P
For alternative basic modules that can be used to supply power to the extension module TS-
AC E2-M3-1X, please refer to the table
This setup can deviate from:
 Use of a different basic module
 Use of additional extension modules
 Connection according to exercise instructions (e.g. by Bosch Rexroth Academy)
For connection of the extension module:
1.
Use the provided network cable () to connect the Ethernet port XF6 () of
IndraControl PR21 to Ethernet port XF6 () of the bus coupler
2.
Use the network cable () to connect the Ethernet port XF7 () of the bus coupler to
the Ethernet port () of the PC
The actions are illustrated in the following figure.
Ethernet port XF6 (PR21)
Ethernet port XF6 (Bus coupler)
Ethernet port XF7 (Bus coupler)
Network cable connection
Connection of network cables is completed.
8.1.2

Setting the IP addresses

For network connection, all connected participants must be within the same IP address
range. Particularly the first 3 octets of the IP addresses must correspond to each other. The
4th octet is assigned to the respective participant. General information about IP addresses
can be found in the figure
„Available basic
„Principle structure of an IPv4
modules" as of page [17].
Ethernet port (PC)
Network cable from scope of delivery
Network cable (not scope of delivery)
address" as of page [56].