Download Print this page
Sealey GA70CR Instructions

Sealey GA70CR Instructions

Calibration rig for ga70

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general
workshop practice regulations are adhered to when using this
calibration rig.
Maintain the calibration rig in good condition (use an
authorised service agent).
replace or repair damaged parts. Use genuine parts only.
Non-authorised parts may be dangerous and will invalidate
the warranty.
Locate calibration rig in a suitable working area, keep
area clean and tidy and free from unrelated materials.
WARNING! use calibration rig on level and solid ground.
Keep the calibration rig clean to ensure accurate performance.
DO NOT use calibration rig outside in damp or wet weather
conditions.
DO NOT allow untrained persons to operate the calibration rig.
DO NOT leave the calibration rig unattended.
2.
INTRODUCTION
used to check and adjust the alignment of the lasers on the GA70
four-Wheel Laser Aligner. this unit will allow workshops to check
and adjust in-house. Laser heads secure to the rig and rest on the
bobbins that contact the vehicle's wheel rim. supplied with
comprehensive instructions.
InstructIons for:
CALIBRATION RIG FOR GA70
GA70CR
MoDEL no:
1.2
LASER SAFETY
the GA70cr calibration rig is used is used in
conjunction with units from the GA70 which utilise
a class II laser that emits low levels of visible
radiation (i.e. wavelengths between 400 and 700
nanometres which are safe for the skin but not
inherently safe for the eyes. the class II emission limit is set
at the maximum level for which eye protection is normally
afforded by natural aversion responses to bright light.
Accidental eye exposure is therefore normally safe, although
the natural aversion response can be overridden by
deliberately staring into the beam, and can also be influenced
by the use of alcohol or drugs.
 WARNING! Do not look or stare into the laser beam as
permanent eye damage could result.
 DO NOT direct the laser beam at any person's (or animal's)
eyes as eye damage could result. If the beam is
obstructed by a person during use, release the contact
switch immediately.
 DO NOT use the equipment while under the influence of
alcohol, drugs or whilst on medication.
 Be aware that reflections of the laser beam from mirrors
or other shiny surfaces can be as hazardous as direct eye
exposure.
Original Language Version
fig.1
GA70cr
Issue: 1 - 05/05/11

Advertisement

loading

Summary of Contents for Sealey GA70CR

  • Page 1 GA70CR MoDEL no: thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.