Troubleshooting

Problem 
Mixer will not run. 
Mixer stops during 
mixing .     
Mixer is noisy.     
Safety  guard  seized 
(will 
not 
move 
freely). 
Agitators won't go 
onto the planetary   
shaft easily.     
Agitators touching 
bottom or sides of 
bowl.     
 
 
Possible Causes 
bowl guard not in closed 
position. 
bowl not raised. 
Timer is not engaged. 
Power not connected properly. 
building circuit breaker is off.   
internal overload tripped. 
Gear not engaged.     
internal overload tripped. 
Motor temperature is too high    Voltage is too low, or use wrong agitator or set 
Mixer is not installed on level 
surface. 
bowl not seated correctly or 
clamps not in place. 
Agitator not fitted properly.     
Overloading bowl.     
Planetary ring gear needs more 
grease. 
clean  &  lubricate  slide 
sheath. 
 
lack of lubrication and/or 
cleaning of the planetary shaft. 
Defective or dented bowl.     
Defective agitator. 
Action Required 
rotate guard to the right until fully closed. 
raise bowl to highest position. 
Turn timer to desired time or set time to the 
"on" position. 
check all power connections. Plug into a live 
socket.(Do not use extension cord!) Test socket 
with another item 
check breaker box. 
Press stop button then press reset button. 
(If overload continues to trip, reduce batch size 
and/or adjust recipe!) 
Switch gear fully into position. (Mixer will not 
operate if the speed control lever is positioned in 
between speeds) 
Press stop button then press reset button. 
(If overload continues to trip, reduce batch size 
and/or adjust recipe!) 
incorrect speed. 
adjust surface or relocate mixer. Make sure 
rubber feet are installed. 
ensure bowl is seated into bowl cradle correctly 
and bowl clamps are locked into place. 
Remove and attach agitator into position 
properly. 
reduce batch size. (See Capacity Chart) 
Technician to inspect for source of noise. 
reapply high‐pressure grease. contact technician. 
Technician must drop down planetary assembly to 
access mat & sheath. contact technician. 
 
Wipe planetary shaft with a clean damp cloth and 
lubricate the shaft with mineral oil or food quality 
grease. 
 
remove dents or replace bowl. 
replace agitator. 
11