8.0 WIRING DIAGRAMS
Generally, for the control of the electric hoists reversive electric diagrams are used.
Meaning of designations are as follows:
L1. L2, L3 - electric network phases
S1 - stop button
T1 - transformer
F1, F2, F3 - safety fuses
Q - Main contactor
Push buttons:
S2 - control cut-out switch button for LOWERING
S3 - control cut-out switch button for LIFTING
S4 - control cut-out switch button for RIGHT movement
S5 - control cut-out switch button for LEFT movement
S6 - end switch
M - Electric motor
K1-K8 – contactors
K9 – contactor time relay
B1 - load limiter electronic block
Wire Rope Hoist
PAGE: 54