Download Print this page

ABB T&B TBM6PCR-LI Operating Instructions page 3

Hydraulic compression tool

Advertisement

Parts and Accessories:
• Hydraulic Compression Tool (TBM6PCR-LI)
Ram
Release button
Advance trigger
Battery
• Battery (BAT-MK)
• Charger (CHR-MK)
Air vent
Contacts
• Tool Hand Bag
Operating Instructions:
Charging the battery
1. Connect the battery charger BAT-MK to 120V AC. Charging
Hanging strap
2. Insert the Battery firmly into the charger. The LED Lamp lights
Hanging strap
3. Full charge (100%) achieved in approximately 45 minutes. LED
Hanging strap
4. When the battery will no longer charge or hold a charge, the
5. When the charger is out of order, the LED Lamp does not light
Contacts
Attaching & Detaching the battery pack
1. Slide Battery into the base of the Tool until it stops and the
LED lamps
2. Gently pull Battery without pressing the latches.
3. To detach, pull out the Battery while pressing the latches.
light will repeatedly flash green.
in red [CHARGING] and a brief preset melody will play. NOTE: If
one or more lights flash red [HIGH TEMPERATURE], allow
battery to remain in charger until cool before charging can
initiate. NOTE: Do not place any foreign objects in the Charger.
lamp lights green and melody or beep will indicate
completion.
LED Lamp blinks alternately from green to red
[IMPOSSIBLE TO CHARGE].
up even if AC power is supplied. NOTE: Do not power the
Charger with a portable generator or any other power source
other than 120V AC.
Charger
latches engage.
Latch
Battery
Pull out
3 of 5
Battery
LED Lamps
Tool
Slide in

Advertisement