INSTRUCTIONS FOR USE
October 1st 2019
EN109-1400912-4E IFU
``

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MANUMED and is the answer not in the manual?

Questions and answers

Summary of Contents for Enraf Nonius MANUMED

  • Page 1 MANUMED INSTRUCTIONS FOR USE October 1st 2019 EN109-1400912-4E IFU...
  • Page 2: Table Of Contents

    INDEX FOREWORD ......................... 3 SYMBOLS ..........................4 INTENDED USE AND INTENDED USER ................5 PACKAGE CONTENTS ......................5 INSTALLATION ........................5 PRECAUTIONS ........................6 7. OPERATION ........................8 SAFETY INSTRUCTIONS ..................... 14 MAINTENANCE ......................... 16 10. SPECIFICATIONS ....................... 18 11. CONTACT .......................... 21 12.
  • Page 3: Foreword

    1. FOREWORD We are pleased that you have purchased a Manumed treatment couch. This examination and treatment couch is specially designed for the demands of the physical and manual therapist. The anatomically segmented top part combined with the wide array of section positions enable you to position your patient virtually however you wish.
  • Page 4: Symbols

    2. SYMBOLS Follow the instructions in the Instructions for Use. It is important that you read, understand, and observe the precautionary and operating instructions Indicates a hazardous situation which, if not avoided, could result in: a. Death or serious injury to the patient or operator (or) b.
  • Page 5: Intended Use And Intended User

    The couches are intended ONLY to be used to support patients during physical and manual therapy. The Manumed couches are designed to ONLY be used by or under the supervision of competent personnel in physiotherapy, rehabilitation, or adjacent areas. 4. PACKAGE CONTENTS •...
  • Page 6: Precautions

    Never adjust a section when it supports the full weight of the patient! Each section of this Manumed is supported by gas springs. As well as easing operation, they offer full support of the sections. However, these gas springs are not strong enough to lift a section while it supports the full weight of the patient.
  • Page 7 When adjusting this couch, keep hands away from the couch for at least 20 cm, especially on places that have been marked by the hand crush warning symbol. The maximum traction force with the Manumed Special Traction (type 004, 916 and 926) is 900 N (90 kg).
  • Page 8: Operation

    7. OPERATION The operation of your Manumed treatment couch is simple and safe. The illustrations show how the various adjustments are done OVING THE COUCH The couch can be moved by using the foot pedal to lower the wheels. NOTE: Never move the couch with a person or load on it.
  • Page 9 REATMENT TABLE WITH ELECTRICAL RAINAGE RENDELENBURG POSITION This table takes over some tilting tasks from you, even with a patient lying on it, e.g. in situations like: table switch ▲. Drainage up: press 1: table switch ▼. Drainage down: press 2: Trendelenburg up: table switch ▲, and pull 3: use one press 1:...
  • Page 10 Head section: pull the handle underneath the head section and adjust the head Manumed type 400 section in the desired position. Leg section: pull the handle underneath the leg section and adjust the leg section in the desired position.
  • Page 11 DJUSTMENT OF THE HORIZONTAL POSITION ON ANUMED STEO The Manumed Osteo with electric section adjustment fitted with programmable operating buttons. A = electric operation back-section A. Use the electric operation A and B to adjust the B = electric operation sitting-section sections up and down independently.
  • Page 12 OW TO REMOVE THE UNLOCK BUTTON OF ANUMED STEO Your Manumed Osteo is provided with the unlock-button on the head-section, it can be removed as follows: • Adjust the head-section in a horizontal position • Remove the unlock-button by pulling it out •...
  • Page 13 Changing the height of the circular switch bar: EN109-1400912-4E IFU Page 13 of 22...
  • Page 14: Safety Instructions

    8. SAFETY INSTRUCTIONS EIGHT ADJUSTMENT GENERAL Ensure that neither the patient nor the operator can get any part of the body or clothes near or in between the moving parts of the mechanism when the couch is being raised or lowered. Be particularly careful for those situations indicated below (the couch is set in flexion position combined with the lowest...
  • Page 15 IX ROLLING TOP SECTION Fix all rolling top sections of the Manumed Special Traction (type 004, 916 and 926) when the couch is not actually used for traction treatment (for example in case a client is entering...
  • Page 16: Maintenance

    9. MAINTENANCE !!! IMPORTANT !!! It is very important for the life of the upholstery that it is properly cleaned. Skin oils, perspiration, make-up products, hairspray, etc. and overly aggressive detergents and disinfectants can have a very detrimental effect on the lifespan of the upholstery. CLEANING •...
  • Page 17 TROUBLESHOOTING If you encounter any problem with the Manumed, stop using the couch and contact your supplier. MAINTENANCE • Check the operation of every section adjustment regularly (at least once every month). For correct operation keep the bars of the mechanism clean and free of grease.
  • Page 18: Specifications

    SPECIFICATIONS TECHNICAL DATA Mains voltage: 230V ˜ Frequency: 50/60 Hz Duration of continues operation short-time operation, 4 minutes maximum. Moisture resistance according IP 44 Optimal 3-section 204 x 67/57/80 47 - 97 200 kg Optimal 3-section 204 x 67/57/80 47 - 100 200 kg 2,0 A Optimal 3-section...
  • Page 19 Osteo 4-section 214 x 67 51 - 103 200 kg 2,0 A 3 motors Osteo 6-section 214 x 67 51 - 103 200 kg 2,0 A 3 motors Osteo 7-section 214 x 67 51 - 103 200 kg 2,0 A 3 motors Comfort 3-section 200 x 67...
  • Page 20 Type B Applied part This equipment complies with all requirements of the Medical Device Directive (93/42/EEC). ORDERING INFORMATION For the ordering data of the Manumed, standard accessories and additional accessories we refer to http://www.enraf-nonius.com ENVIRONMENT CONDITIONS Environment conditions for Transport and Storage Environment temperature: -10 to +50 °C...
  • Page 21: Contact

    CONTACT www.enraf-nonius.com For assistance and support, please visit our website The most recent version of these Instructions for Use (in electronic or printed form) can be obtained free of charge via our website www.enraf-nonius.com, by contacting your supplier or by calling +31 (0)10 2030600. The Instructions for Use will be sent (free of charge) within 7 (seven) calendar days.
  • Page 22 Copyright: Enraf-Nonius B.V. Vareseweg 127 | 3047 AT | Rotterdam | The Netherlands Tel: +31 (0)10 20 30 600 | info@enraf-nonius.nl EN109-1400912-4E IFU...