  • Page 1 Operating Instructions (101703) TAIFUN-CLEAN 014/015/016 Translation of the Original Instructions (EN) Dr. Escherich GmbH Höglwörther Straße 1 81369 München · Germany Phone +49 (0)89 31 85 55-0 E-mail info@dr-escherich.com www.dr-escherich.com Version: 3 • 28/08/2019 Subject to technical changes...
  • Page 2: Table Of Contents

    4.1 Mechanical Fixing ........................ 17 4.2 Compressed Air Connection.................... 18 4.3 Rotation Control (Optional).................... 20 4.4 Suction Connection ........................  20 4.5 Electrical Cables and High Voltage Supply................ 21 4.5.1 Electrical Cables and High Voltage Supply for AC Ionisers .......... 21 TAIFUN-CLEAN 014/015/016...
  • Page 3 7.8 Cleaning the Output Air Component.................. 31 8 Disposal...........................  32 9 Technical Data .........................  33 10 Spare Parts and Accessories.....................  34 10.1 Spare Parts .......................... 34 10.2 Accessories .......................... 34 11 Drawings and Order Keys...................... 36 12 Declaration of Incorporation.................... 38 TAIFUN-CLEAN 014/015/016...
  • Page 4: User Instructions

    1 | User Instructions 1 User Instructions 1.1 About These Operating Instructions These operating instructions apply to: ▪ TAIFUN-CLEAN 014 (TC014) ▪ TAIFUN-CLEAN 015 (TC015) ▪ TAIFUN-CLEAN 016 (TC016) These operating instructions are an integral part of the product and must be available at any time.
  • Page 5: Explanation Of Warning Messages

    Indicates important information about the product or useful tips. 1.5.2 Structure of Warning Messages Section safety messages Section safety messages apply to entire chapters or sections of these operating instruc- tions. Section safety messages are structured as followed: TAIFUN-CLEAN 014/015/016...
  • Page 6: List Of Safety Symbols Used

    1.5.3 List of Safety Symbols Used In these operating instructions the following safety symbols are used: Safety sym- Meaning Dangerous area Dangerous electrical voltage Danger of crushing Risk of injury due to sharp parts Do not touch Coaxial plugs under high voltage TAIFUN-CLEAN 014/015/016...
  • Page 7: Table 1 List Of Safety Symbols Used

    User Instructions | 1 Safety sym- Meaning Danger from loose compressed air lines and connectors Mandatory action: Wear ear and eye protection ESD-protected areas Table 1: List of safety symbols used TAIFUN-CLEAN 014/015/016...
  • Page 8: General Safety Instructions

    Pneumatic installa- tions Start-up mechanical and pneumatic Start-up electrical Mechanical mainten- ance, troubleshoot- ing and repair Electrical mainten- ance, troubleshoot- ing and repair Cleaning Safety inspection Disconnecting the power supply cables Disconnecting the pneumatic supply hoses Dismantling TAIFUN-CLEAN 014/015/016...
  • Page 9: Special Dangers

    2.3.4 Dangers from the Pneumatic Equipment Loose compressed air lines and connectors can cause severe injury. Shut off the compressed air supply during installation and maintenance via the factory main valve. Compressed air can move particles into the eyes of user. TAIFUN-CLEAN 014/015/016...
  • Page 10: Risk Of Injury Due To Material Transport Near The Device

    Persons with heart pacemakers must keep a safety distance of 50–100 cm (depend- ing on the model, see the operating instructions for the ioniser) from: ▪ the ioniser discharge tips ▪ HV transformers of the ionisation power supplies if present TAIFUN-CLEAN 014/015/016...
  • Page 11: Physical Complaints Due To Too Much Ozone

    High voltage is applied to coaxial plugs of AC ionisers. When the HV supply is switched on and coaxial plugs are being plugged in or out, an arc may occur and damage the socket of the HV supply and the coaxial plug of the AC ioniser. TAIFUN-CLEAN 014/015/016...
  • Page 12: Safety Measures In Esd-Protected Areas

    Plug in and out coaxial plugs of the AC ionisers only when de-energised. 2.4 Safety Measures in ESD-Protected Areas Electrostatic discharge can cause defects in customer's electronic components en- dangered by ESD. Assure personal earthing via wrist and shoe earthing. Wear only clothes which are static dissipative and closed. TAIFUN-CLEAN 014/015/016...
  • Page 13: Product Description

    NOTICE Equipment damage due to electrostatic discharge Electrostatic discharge can cause defects in customer's electronic components en- dangered by ESD. Assure personal earthing via wrist and shoe earthing. Wear only clothes which are static dissipative and closed. TAIFUN-CLEAN 014/015/016...
  • Page 14: General View

    The particles are gathered by means of a special suction geometry, transported to the suction channel , item 1) and further transported to an external filter  Fig. 2, p. 15 unit. TAIFUN-CLEAN 014/015/016...
  • Page 15: Fig. 2 Function Principle

    Product Description | 3 Fig. 2: Function principle Item Name Suction channel Rotating nozzle Ioniser Object to be cleaned TAIFUN-CLEAN 014/015/016...
  • Page 16: Installation

    Activate all safety equipment and ON/OFF switch before start-up. Approach the device only when the entire system is switched off. Before initial start of the entire system, check that all tools and foreign objects have been removed. TAIFUN-CLEAN 014/015/016...
  • Page 17: Mechanical Fixing

    Machine components which are earthed must not be located between the ioniser and the part to be cleaned or in the immediate vicinity of the ionisers. No additional components must be placed between ionisers and product surface (Ex- ception: electrically non-conductive or insulated slide or retaining elements if neces- sary). TAIFUN-CLEAN 014/015/016...
  • Page 18: Compressed Air Connection

    See } 9 Technical Data 1.5–3.5 [p. 33] Table 4: Compressed air connection for the cleaning system 1. The recommended operating pressure is between 1.0 (or 1.5) and 3.5 bar. This pressure range guarantees the rotating speed of the nozzle which was factory ad- justed. TAIFUN-CLEAN 014/015/016...
  • Page 19: Fig. 4 Compressed Air Consumption Tc014

    The operating air pressure in the rotating nozzle must not exceed the maximum permitted air pressure. 1.0 bar 2.0 bar (standard) 3.5 bar Working width (mm) Fig. 4: Compressed air consumption TC014 1.0 bar 2.0 bar (standard) 3.5 bar Working width (mm) Fig. 5: Compressed air consumption TC015 TAIFUN-CLEAN 014/015/016...
  • Page 20: Rotation Control (Optional)

    ESD-protected areas The conductive suction hose is contacted via the pointed screw of the ESD hose clamp. The green or green-yellow cable on the hose clamp can be additionally connected to earth. However, this is not strictly necessary. TAIFUN-CLEAN 014/015/016...
  • Page 21: Electrical Cables And High Voltage Supply

    Earthing for the ionisers is provided via the existing HV cable and plug. No extra earth- ing is required. Detailed information, e.g. the maximum connection length, can be referred to in the operating instructions of the ionisers and HV power supplies. TAIFUN-CLEAN 014/015/016...
  • Page 22: Electrical Cables And High Voltage Supply For Dc Ionisers

    The LV cables of the DC ionisers are connected to the power supply via screw connect- ors. Consult the operating instructions for the DC ionisers. 4.5.3 Earth Connection ESD-protected areas Connect a suitable earth cable with ring cable lug to the cleaning device at the in- tended earthing point. TAIFUN-CLEAN 014/015/016...
  • Page 23: Start-Up

    In this case the warranty becomes invalid. The operating air pressure in the rotating nozzle must not exceed the maximum permitted air pressure. 5. Optimise the blowing effect by adjusting the compressed air via the filter control valve. 6. Switch on suction system. TAIFUN-CLEAN 014/015/016...
  • Page 24 Check function of the ionisers using the ION CHECK function tester (see the operat- ing instructions for ION CHECK). By using the ION CHECK SENSOR device, continuous monitoring is possible. Measure the electrostatic surface charges on components and web using the field strength meter ELFI 1. TAIFUN-CLEAN 014/015/016...
  • Page 25: Troubleshooting

    ▪ Let a qualified electrician check the installation. ▪ Are the ionisers connected to a suitable power supply? ▪ Is the supply voltage the same as the defined on the manufacturer's specification plate? ▪ Is the power supply switched on? TAIFUN-CLEAN 014/015/016...
  • Page 26: Troubleshooting The Compressed Air Supply

    ▪ Are the suction unit filters heavily contaminated? 6.5 Cleaning Result Is Unsatisfactory An unsatisfactory cleaning result can have various causes: ▪ The compressed air supply and therefore the air nozzles are not operating cor- rectly. ▪ The ionisation is not operating correctly. TAIFUN-CLEAN 014/015/016...
  • Page 27 Troubleshooting | 6 ▪ The positioning of the component to the cleaning device is not optimal. Ask your responsible Dr. Escherich sales partner for advice. TAIFUN-CLEAN 014/015/016...
  • Page 28: Maintenance

    1. Remove the cover disc, if present, by loosening the screws. 2. Set the mounting tool TCK7 on the rotating nozzle. 3. Turn the mounting tool TCK7 in a clockwise direction, until the rotating nozzle is hand-tight. 4. If necessary, mount the cover disc again. TAIFUN-CLEAN 014/015/016...
  • Page 29: Service For The Rotating Nozzles

    Please send the rotating nozzle for servicing or repair with a description of the faults and if possible with the purchase date to: Dr. Escherich GmbH Reparaturabteilung Lockwitzgrund 100 01257 Dresden...
  • Page 30: Warranty For The Rotating Nozzles

    The emitters of the ionisers are sharp and can cause injury. Do not touch the emitter tips. 1. Release attachment screws as shown in  Fig. 8, p. 31 2. Carefully pull out the ioniser in the direction shown. 3. Fit replacement ioniser by working in reverse order. TAIFUN-CLEAN 014/015/016...
  • Page 31: Maintenance Of The Ionisers

    1. Remove the particle accumulations in the device. 2. If necessary, wipe the device with a damp cloth on the outside. 3. If the device is equipped with suction channel: If necessary, clean the inside of the suction channel. TAIFUN-CLEAN 014/015/016...
  • Page 32: Disposal

    They are either recycled by us or disposed of by a recyc- ling company in conformity with legal obligations. For inspection, repair or disposal, please return the device to the following address after previous arrangement: Dr. Escherich GmbH Reparaturabteilung Lockwitzgrund 100 01257 Dresden...
  • Page 33: Technical Data

    TCR-7A-130 200–2000 5.5/200 DN19 DN9 to DN19 de- pending on TC015 TCR-7A-070 100–2000 1.9/100 working width also on both sides DN13 to DN16 de- pending on TC016 TCR-7A-070 100–1500 1.2/100 working width also on both sides Table 8: Technical data TAIFUN-CLEAN 014/015/016...
  • Page 34: Spare Parts And Accessories

    Cover disc for rotating nozzle TCR-7A-130 100452 Table 10: Accessories for TAIFUN-CLEAN rotating nozzles Figure Model Description Order no. TCK7 Tool for mounting rotating nozzle 100321 Air guide Guide plate for optimising suction ef- On request plate fect (for TC014/015/016) TAIFUN-CLEAN 014/015/016...
  • Page 35: Table 11 Accessories For Taifun-Clean

    HV supply Supply unit with compressed air con- Combi-Box 101730 trol, HV supply Filter control valve for various com- pressed airflow rates with special fine On request filter, manometer, water and special oil separator Table 11: Accessories for TAIFUN-CLEAN TAIFUN-CLEAN 014/015/016...
  • Page 36: Drawings And Order Keys

    Version (e.g. ESD, CR) Model Fig. 10: Ordering example TC014 Working width Working width + 6 Fig. 11: Drawing TC015 Ordering example TC015ESD-0800-02-ZZZ Ionisation type Cable length (m) Working width (mm) Version (e.g. ESD, CR, US) Model Fig. 12: Ordering example TC015 TAIFUN-CLEAN 014/015/016...
  • Page 37: Fig. 13 Drawing Tc016

    Drawings and Order Keys | 11 Working width Working width + 6 Working width + 36 Fig. 13: Drawing TC016 Ordering example TC016ESD-0800-R(L)-02-ZZZ Ionisation type Cable length (m) Right/left version Working width (mm) Version (e.g. ESD, CR) Model Fig. 14: Ordering example TC016 TAIFUN-CLEAN 014/015/016...
  • Page 38: Declaration Of Incorporation

    12 | Declaration of Incorporation 12 Declaration of Incorporation TAIFUN-CLEAN 014/015/016...
  • Page 39 Replacing the ionisers ......................31 Fig. 9 Drawing TC014 ........................36 Fig. 10 Ordering example TC014...................... 36 Fig. 11 Drawing TC015 ........................36 Fig. 12 Ordering example TC015...................... 36 Fig. 13 Drawing TC016 ........................37 Fig. 14 Ordering example TC016...................... 37 TAIFUN-CLEAN 014/015/016...
  • Page 40 Table 5 Maintenance plan TAIFUN-CLEAN..................Table 6 Maintenance plan rotating nozzles ..................Table 7 Maintenance plan ionisers ....................Table 8 Technical data ........................Table 9 Spare parts ......................... Table 10 Accessories for TAIFUN-CLEAN rotating nozzles ..............Table 11 Accessories for TAIFUN-CLEAN................... TAIFUN-CLEAN 014/015/016...
  • Page 43 PRODUKTÜBERSICHT PRODUCT OVERVIEW ELEKTROSTATIK ELECTROSTATICS Aufladesysteme Charging Systems Elektrostatische Entladung – Electrostatic Discharge – Nahbereich Shortrange Elektrostatische Entladung – Electrostatic Discharge – Größere Reichweiten Widerange REINIGUNGSSYSTEME CLEANING SYSTEMS Manuelle Reinigung Manual Cleaning Reinigung von 3D- Cleaning of Geometrical Geometrien Parts Reinigung von Bahnen und Cleaning of Webs and flachen Geometrien...
  • Page 44 Eine vollständige Produktübersicht finden Sie in unserem Dr. Escherich Gesamtkatalog oder unter www.dr-escherich.com For a complete product overview please see our Dr. Escherich catalogue or online at www.dr-escherich.com Dr. Escherich GmbH Höglwörther Straße 1 81369 München · Germany Phone +49 (0)89 31 85 55-0 E-mail info@dr-escherich.com...