Page 1
PHOTOVOLTAIC CHARGE CONTROLLER RSD30 RSD50 Soluciones Energéticas S.A. AV Real de Pinto, 146 - 28021 Villaverde Alto, Madrid Phone 91 539 27 00 https://www.solener.com solener@solener.com User guide version 1.1.2006, for controllers version 3.04...
Page 2
Soluciones Energéticas Soluciones Energéticas S.A. AV Real de Pinto, 146 28021 Villaverde Alto, Madrid Phone: 91 539 27 00 https://www.solener.com solener@solener.com INSTALLATION The RSD controller itself is protected against polarity inversions, but you must be careful when connecting it because the loads and even the modules can be damaged when the battery polarity is reversed.
Page 3
- Low and high battery voltage, overload and short circuit alarms reported with LED, LCD display and acoustic signal. The acoustic signal can be silenced temporarily pressing a key or forever (if it bothers somebody) by removing an internal jumper marked BZ. www.solener.com solener@solener.com...
Page 4
The smart diode blocks current flow from the battery to the modules at night, and has very low losses when the current flows from modules to battery. It is not an usual diode, so do not make assumptions about how it works. www.solener.com solener@solener.com...
Page 5
The high battery alarm usually indicates a problem in the installation (battery with low electrolyte level, rusted bridges or loose screws...). Please call your installer as soon as possible, because there is a risk of damage or even fire. www.solener.com solener@solener.com...
Page 6
• Battery voltage and selected battery. • Battery status and charge mode. • Current, minimum and maximum temperature. • Energy since last reset (in W·h). • Input power, current and peaks. • Output power, current and peaks. • www.solener.com solener@solener.com...
Page 7
This function allows the use of the controller for street lights, beacons and other. The 50 A model does not have smart diode, so the beacon function is not available and the output never activates. BATTERY Tubular vented SOPzS Tubular gel AGM* Battery selection www.solener.com solener@solener.com...
Page 8
CAN'T BE USED in battery systems. In a 12 V system you must use 36 to 40-cell modules, while in a 24 V system you must use 72 to 80-cell modules (or two 12 V modules in series). www.solener.com solener@solener.com...
Need help?
Do you have a question about the RSD30 and is the answer not in the manual?
Questions and answers