Forged gate valves class 800 with threaded, socket weld or flange ends (7 pages)
Summary of Contents for Genebre 2415
Page 1
Genebre Building. Av. de Joan Carles I, 46-48 08908 L'Hospitalet de Llobregat. Barcelona (Spain) genebre@genebre.es - www.genebre.es INSTALLATION, OPERATION AND MAINTENANCE MANUAL Disk check valve GENEBRE Reference: 2415 GENEBRE S.A. LAST UPDATE: 07/09/2009 UPDATE NUMBER: 0...
Page 2
Genebre Building. Av. de Joan Carles I, 46-48 08908 L'Hospitalet de Llobregat. Barcelona (Spain) genebre@genebre.es - www.genebre.es Installation, operation and maintenance instructions 1. Breakdown drawing......................3 1.1) List of valve components ....................3 2. Storage ..........................4 3. Installation instructions ......................4 3.1) Preparation ........................4 3.2) Assembling ........................4...
Page 3
Genebre Building. Av. de Joan Carles I, 46-48 08908 L'Hospitalet de Llobregat. Barcelona (Spain) genebre@genebre.es - www.genebre.es 1) Breakdown drawing. 1.1) List of valve components Part. Nr. Description Quant. Material Finishing BODY Blasting + Pickling DISK Blasting + Pickling SPRING COVER GENEBRE S.A.
Page 4
Genebre Building. Av. de Joan Carles I, 46-48 08908 L'Hospitalet de Llobregat. Barcelona (Spain) genebre@genebre.es - www.genebre.es 2) Storage In case valve is not immediately installed, it is recommended to keep it inside the included protective wrapping to avoid damages or dirt accumulation. The wrap must not be removed until valve is to be installed.
Page 5
- www.genebre.es IMPORTANT: - Check disk valves by Genebre, S.A. are designed to be assembled between flanges DIN PN16, DIN PN25, DIN PN40 and ANSI 150. - Be extremely cautious when placing the valve in the center of the pipe axis to assure tightness between the body and the flange.
Page 6
In both cases it will be necessary to disassemble the valve for repairing it. GENEBRE, S.A. has replacement springs (part. 3). However, it may be the case that (for example, in an area difficult to access), due to financial reasons, it is not recommended to repair the valve but directly replace it.
Page 7
Install again the valve between flanges. See Installation instructions on page 4. 7.) Pressure for opening Disk check valve by GENEBRE, S.A. (art.2415) has been designed to work with minimal operational pressures (to obtain more information, please consult the technical specifications).