Power failure (Power ?)
This red LED blinks as long as
interrupted and the unit is not in guard mode.
If
is disconnected from the main power supply for more than 3 hours, the
BANDIT
internal heat exchanger will cool down too much to have a decent performance.
will detect this and will refuse to eject fog. Fog ejected through a too cold
BANDIT
heat exchanger is wet, which could damage the surroundings (greasy film
on textile, documents, furniture, etc...). As soon as the main power supply is available
again, the unit will start to re-heat its heat exchanger and to re-charge its internal
battery.
Informative PCB LED
Error LED
(red LED, location on PCB, see page 9):
reports its internal failure through its front LED "Failure" and its technical output
BANDIT
[OKout]. To provide the installer with more information about the kind of failure reported, there
is located a red error info-LED [Error] on the PCB. If this LED starts blinking, a failure is
reported, whereby the frequency of blinking reveals the kind of failure.
The blinking sequence is built up in repeating time blocks of 10 seconds.
Blink-
frequency
Reported failure
Glass fuse F2 and/or F3 blown
1 x
2 x
Charge of disconnected battery too low
3 x
Charge of connected battery too low
HY-3 pack above 50°C.
4 x
The MCU measures unreal value(s)
5 x
on the Control Box PCB-connector.
6 x
Internal MCU failure
Incorrect temperature of heat exchanger
7 x
Ventilator doesn't turn
8 x
9 x
The
MCU measures unreal value(s)
With simultaneous failure reports, e.g. "F3 blown" and "load connected battery too low", this
LED will blink 1 x every 10 seconds. If the first failure is restored, in this case "fuse replaced",
the LED will blink 3 x every 10 seconds to report the next failure, in order of the list above.
BANDIT detects
P. 23 - Communication status - LEDs - Front LEDs & Error LED
BANDIT 240 DB
its power supply or its main fuse F1 is
Action installer
Check F2 and/or F3
Battery problem
Battery- or power supply
problem.
Environmental temperature
too high or dusty textile front
Control Box connecting cable
and/or check position dip B3.
Push-in r
success, back to factory
Back to factory
Back to factory
Back to factory
v.206
eset switch, if no
Need help?
Do you have a question about the 240 DB and is the answer not in the manual?
Questions and answers