HRC-EcoSmart / HRC-SmartComfort
Balanced ventilation with heat recovery &
zone control
This manual is intended for the users of the HRC-EcoSmart and HRC-
SmartComfort balanced ventilation system. The manual contains important
information about the operation and maintenance of the ventilation unit with
heat recovery and zone control.
These instructions belong to the versions:
HRC-425-EcoSmart
HRC-425-SmartComfort
HRC-570-EcoSmart
HRC-570-SmartComfort

Advertisement

loading
Need help?

Need help?

Do you have a question about the HRC-EcoSmart and is the answer not in the manual?

Questions and answers

Summary of Contents for Orcon HRC-EcoSmart

  • Page 1 HRC-EcoSmart / HRC-SmartComfort Balanced ventilation with heat recovery & zone control This manual is intended for the users of the HRC-EcoSmart and HRC- SmartComfort balanced ventilation system. The manual contains important information about the operation and maintenance of the ventilation unit with heat recovery and zone control.
  • Page 2: Table Of Contents

    Table of contents Precautions and safety instructions General operation balance ventilation system Product informatie Controlling the device Maintenance Faults Certification and warranty...
  • Page 3 Why ventilate? Orcon: exceptional indoor climate Our goal is to provide residents with the most comfortable and healthy (extraordinary) indoor climate possible, in which they feel comfortable and can function optimally. The importance of good ventilation Houses are increasingly well insulated. This is a good development, because it saves a lot of energy and money.
  • Page 4: Precautions And Safety Instructions

    Note: It is not permitted to connect a motorised extractor hood or a tumble dryer to the system. 1. Precautions and safety instructions 1.1.Safety regulations • Installation, commissioning and maintenance must be carried out by a recognised installer, unless otherwise indicated. An unauthorised installer may cause personal injury or damage to the functioning of the ventilation system;...
  • Page 5 In order to create a healthy living environment in your home, good ventilation is required. Your house is therefore equipped with an Orcon mechanical supply and exhaust ventilation system. This system consists of a centrally installed balanced...
  • Page 6 And the air supply in the bedroom is kept optimal. This makes the HRC-EcoSmart/Comfort very energy-efficient as it only ventilates the room where it is needed. As a result, the ventilation system is also whisper- quiet.
  • Page 7 Attention: Ensure sufficient air supply. Never tape valves together or close them! Please contact your installer if you have any questions or if you want to order new filters. Filters can also be ordered directly in the Orcon webshop: www.orcon.nl/winkel Filters The HRC is equipped with two filters.
  • Page 8: Product Informatie

    65% coarse 65% In accordance with Article 3.29 Paragraph 5 of the 2012 Building Decree 3.2.Optional accessories The unit can be expanded with the Orcon articles listed in the table below. Article Article number Remote control 15RF 21800000...
  • Page 9 room sensor 15RF 21800040 sensor 15RF 21800050 control sensor 15RF 21800045 HRC built-in display 15RF 21800060...
  • Page 10 4. Operating the appliance The HRC can be operated with various accessories. This chapter describes how to use the optional controls. For a detailed description, please refer to the operating instructions of the respective control. 4.1.Operation with 3 position switch If your unit has a perilex connection and a 3 position switch, the ventilation positions from the table below can be set.
  • Page 12 Absence mode In the absence mode, the unit runs in the minimum ventilation mode. Timer mode In timer mode, the unit runs for a desired time in position high, after the time has elapsed the unit returns to the last selected position. The timer can be cancelled by selecting another (desired) setting.
  • Page 13 4.4.Control with the built-in sensor This built-in sensor measures the (air quality) in the room and CO2 concentration automatically increases ventilation when necessary. This prevents unnecessary ventilation, which benefits the energy efficiency of the device. Indication and operation with the built-in sensor By pressing the operating button once, the status is shown by the LEDs.
  • Page 14 Energy-saving Automatic regulation on the basis of <1150 PPM Auto mode Outstandingly Automatic control based on <950 PPM Good Auto Mode...
  • Page 15 built-in sensor has the following modes: • Absence and positions 1, 2 and 3 When the recessed sensor is in the off position, the unit will ventilate a minimum amount. Only the Status LED lights up and goes out after 30 seconds.
  • Page 16 It is possible to place a room sensor, flush-mounted sensor and/or flush- mounted display or control sensor in each occupied room. This can be extended to up to 15 Room sensors (and 5 remote controls). These sensors communicate wirelessly with the HRC-EcoSmart/SmartComfort ventilation unit.
  • Page 17 When the remote control is set to automatic mode, the unit responds to the highest level (air quality in a residential area) measured by the room sensors. This provides fully automatic control, ensuring an exceptional indoor climate for the occupant at all times. You can always choose a different speed with the remote control.
  • Page 18 4.6.HRC Display Built-in 15RF The HRC can be operated and read with the HRC Display built-in 15RF. The display has control buttons with which the appliance can be operated. It is also possible to use the display to read out the status of the appliance and to change various settings. Indication and operation Built-in display By briefly touching one of the buttons, the display lights up and shows the current status of the connected HRC.
  • Page 19 Temporary stand Appliance runs temporarily in position 3 (60 min)
  • Page 20 Changing fan settings In the standard screen, the fan speed can be changed using the UP and DOWN buttons. Read out device settings Settings of the HRC can be read by pressing the Menu button until the following icon appears in the display. By touching the UP or DOWN button the following settings can be read out.
  • Page 21 Changing settings It is also possible to change device settings with the built-in display. To do this, follow the steps below: 1. Press the MENU button for 10 seconds. 2. When flashing, press the OK key to enter the settings menu. 3.
  • Page 22: Maintenance

    5. Maintenance The parts of the HRC listed in the table below should be cleaned regularly. Cleaning parts Orcon ventilation system Action Interval Who? Cleaning filters 1x per 3 months User Replacing filters 1x per 6 months User or installer...
  • Page 23 2. Take the dirty filters out of the unit using the pull tab. 3. Vacuum the filters on the outside. If the filters are too heavily soiled, they must be replaced. Order original Orcon filters to ensure a good performance of the unit (www.orcon.nl/winkel).
  • Page 24 You can easily replace it yourself. A new battery can be ordered easily at www.orcon.nl/winkel. To replace the battery, press the button on the bottom of the remote control to release the top part from the wall frame.
  • Page 25 User maintenance log Date/ Clean Cleani Cleaning Filling Actio controls condensate filters valves drain...
  • Page 26: Faults

    6. Faults I. Remote control 15RF When a button on the remote control is pressed, the LED lights up green and then flashes as confirmation. The following indications are possible: Indication overview remote control 15RF Indication Message on remote control Device OK, message followed 1x green Device OK, timer 15 min.
  • Page 27 III. Built-in display 15RF An error message is shown in the display with the following icon Overview of indications on the built-in display 15RF Indication Message on display Temperature emergency stop HRC No connection to the zone valves Error both fans Fan supply fault Fan outlet fault Modbus error both fans...
  • Page 28 Indication Led display Binding mode is active Continuous green Pre-heater active 3x long green Frost protection active 2x long green Bypass active 5x short green Timer mode active 4x short green External sensor query active 3x short green Internal RH mode active 2x short green Normal mode 1x short green...
  • Page 29 20 different RF components to the device. For details, please refer to the manual of the respective RF component or www.orcon.nl In operation After the learning mode, the unit will automatically switch to the "in operation"...
  • Page 30 Zone control The HRC EcoSmart and SmartComfort are equipped with a zone valve. Zone valve 1 is equipped with a circuit board with 2 status LEDs. Description indication Normal operating mode (no demand from sensors) 1x Green Humidity scenario active HRC 2x Green demand from sensor 3x Green...