Download Print this page
Allegion LCN 8310-813 Installation Instructions

Allegion LCN 8310-813 Installation Instructions

Touchless acutators

Advertisement

Quick Links

JAMB
TECHNICAL SPECIFICATIONS
Technology:
Radiated frequency:
Radiated power density:
Supply voltage:
to be operated from SELV-compatible
power supplies only
Supply frequency:
Power consumption:
Output
relay contact rating (max. voltage):
relay contact rating (max. current):
Max. switching power:
Detection range:
Detection mode:
Output hold time:
Temperature range:
Weight:
Material:
IP rating:
Certification:
75.0027.01 8310-813 TOUCHLESS ACTUATOR 20200701
SINGLE-GANG
8310-813 TOUCHLESS ACUTATORS
Touchless-activation switch for automatic doors
DOUBLE-GANG
microwave motion sensor
24.125 GHz
< 5 mW/cm
2
12 – 24 VAC ±10%
12 – 24 VDC +30% / -10%
50 – 60 Hz
< 1.5W
relay with switch-over contact (voltage-free)
60 VDC / 125 VAC
1A (resistive)
30W DC / 60 VAC
4 – 24" (adjustable)
motion (bidirectional)
0.5 – 30 sec
-4 – 131 °F (-20 – 55 °C)
0.34 lbs
PC, PE
IP54
Electromagnetic compatibility (EMC) according to 2004/108/EC
FCC: G9B-210161
IC: 4680A-210161
Specifications are subject to change without prior notice.
6" ROUND
All values measured in specific conditions.
Page 1 of 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the LCN 8310-813 and is the answer not in the manual?

Questions and answers

Summary of Contents for Allegion LCN 8310-813

  • Page 1 8310-813 TOUCHLESS ACUTATORS Touchless-activation switch for automatic doors JAMB SINGLE-GANG DOUBLE-GANG 6” ROUND TECHNICAL SPECIFICATIONS Technology: microwave motion sensor Radiated frequency: 24.125 GHz Radiated power density: < 5 mW/cm Supply voltage: 12 – 24 VAC ±10% to be operated from SELV-compatible 12 –...
  • Page 2 FCC APPROVAL This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: *this device may not cause harmful interference, and *this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 3 SET-UP Four adjustments can be made to the sensor: Sensitivity potentiometer: adjust detection field from 4 to 24 inches (rotate clockwise to increase) factory default: 4 inches (fully CCW) Hold time potentiometer: adjust relay hold time from 0.5 to 30 seconds (rotate clockwise to increase) factory default: 0.5 sec (fully CCW) Output Mode switch: determines Toggle mode or Timer mode...
  • Page 4 Allegion at 1-877-671-7011. If you must wait for the following workday to call Allegion, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.