Page 1
8310-813 TOUCHLESS ACUTATORS Touchless-activation switch for automatic doors JAMB SINGLE-GANG DOUBLE-GANG 6” ROUND TECHNICAL SPECIFICATIONS Technology: microwave motion sensor Radiated frequency: 24.125 GHz Radiated power density: < 5 mW/cm Supply voltage: 12 – 24 VAC ±10% to be operated from SELV-compatible 12 –...
Page 2
FCC APPROVAL This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: *this device may not cause harmful interference, and *this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Page 3
SET-UP Four adjustments can be made to the sensor: Sensitivity potentiometer: adjust detection field from 4 to 24 inches (rotate clockwise to increase) factory default: 4 inches (fully CCW) Hold time potentiometer: adjust relay hold time from 0.5 to 30 seconds (rotate clockwise to increase) factory default: 0.5 sec (fully CCW) Output Mode switch: determines Toggle mode or Timer mode...
Page 4
Allegion at 1-877-671-7011. If you must wait for the following workday to call Allegion, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.