Download Print this page

Sony BKM-FW50 Service Manual page 28

Network receiver adaptor
Hide thumbs Also See for BKM-FW50:

Advertisement

5-5. MIB to Be Installed
BKM-FW50 that can be used for Information Display
installs MIB-2.
MIB-2 is the most representative standard MIB. It is
installed in various network products.
The statistical information on the amount of network
traffic or the number of transmitted and received packets is
defined, and the change or transition can be monitored by
polling the information periodically.
Additionally, the management items to be installed can be
defined using a TCP/IP device so as to get the information
effective for the monitoring of the network communication
state.
Refer to RFC1213 for the detailed definition of MIB-II.
5-6. Information to Be Notified on Trap
In software version 2.0 or later, the Information Display
into which the software is inserted mounts a function that
transmits error information to BKM-FW50, so an error trap
is installed. Authentication Trap is also installed.
5-7. ID Talk
ID Talk is set as described below. ID Talk is a protocol for
operating the function of the display equipment, in which
this unit was installed, or the function of this unit via a
network.
5-7-1. Default Setting
Item
Description
Transport
TCP
Port number
53484 (Factory setting)
TCP connection time-out
30 seconds (Factory setting)
5-4
5-7-2. Setting Items
The items that can be set to ID Talk are shown in the table
below.
Item
Description
Start ID Talk Service
Select the check box when using ID
Talk. Clear the check box when using
no ID Talk. (The default setting is OFF.)
Port No.
Changes the port number. A port
number must be able to be changed on
the assumption that port number 53484
cannot be used because it has been
already used for another purpose.
Timeout
Specify the timeout time of connection.
Connection is automatically
disconnected when communication is
not done for the specified time.
IP address of client
Executes only the request from the
(Host Address)
specified IP address.
ID Talk does not have the security
function such as user authentication.
During installation, safety can be
improved by setting this setting item.
Multiple host addresses can be set.
Community
Changes the community of a header.
Set the items described above properly on the SETUP →
ID Talk page of the Web page when using ID Talk.
5-7-3. Packet Structure
The packet structure of ID Talk is described below.
Command
Command
(4)
(4)
Header
(2)
Packet structure
1. Header
The header is constituted by two bytes consisting of a
version (8 bits) and category (8 bits).
0
1
0
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5
Version (8)
Category (8)
Header structure
Version
Indicates the version number of an ID Talk protocol.
This version is fixed to 02h (version 2).
Data
(n)
(Bit position)
BKM-FW50

Advertisement

loading