Advertisement

Data Manager Options
To configure the System Monitor to work with the different data interfaces remove all option
jumpers from headers W3A-W3D, W4A-W4H, W5A-W5H, W7 and W8A-W8E and install jumpers
as specified in Table 1.
Dynamic Data Manager
Transient Data Manager
No Data Interface
Internal
Serial Data Interface/
Dynamic Data Interface
External
Serial Data Interface/
Dynamic Data Interface or
Transient Data Interface
* As shipped from factory for a 3300/03 - 01 System Monitor.
** As shipped from factory for a 3300/03 - 02 or 3300/03 - 03 System Monitor.
-VT Options
To set the -VT option according to the option set on the Power Supply, remove jumpers from
headers W1 and W2 and install jumpers as specified in Table 2.
Table 1. Data Manager Options
OPTION
or
®
or
®
Table 2. -VT Options
OPTION
-VT = -18 Volts
-VT = -24 Volts
Section 7 - PROGRAMMABLE OPTIONS
INSTALL JUMPERS
W3A,W3B,W5A,W5B,W5C,W5D,W5E,*
W5F,W5G,W5H,W8D & W8E
W3C,W3D,W4A,W4B,W4C,W4D,W4E,**
W4F,W4G,W4H,W7,W8D & W8E
W3C,W3D,W5A,W5B,W5C,W5D,W5F,
W5G,W5H,W8A,W8B & W8C
INSTALL
REMOVE
JUMPER
JUMPER
W2
W1
W1
W2