Advertisement

P ERFEC T LY S C E N TE D E N V IR O NM E N TS
AirQ 1570
Updated: 2020-03-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirQ 1570 and is the answer not in the manual?

Questions and answers

Christopher Njoya
April 14, 2025

Hi, What is the code and price for the scenting unit AirQ1570?

1 comments:
Christopher Njoya
April 14, 2025

@Christopher Njoya

Christopher Njoya
April 14, 2025

No, just the purchase procedure.

Subscribe to Our Youtube Channel

Summary of Contents for Prolitec AirQ 1570

  • Page 1 P ERFEC T LY S C E N TE D E N V IR O NM E N TS AirQ 1570 Updated: 2020-03-02...
  • Page 2: Table Of Contents

    Contents Chapter 6: OPERATING INSTRUCTIONS Chapter 1: IMPORTANT SAFETY INSTRUCTIONS Features and Controls Appliance Precautions Setting Up the Cartridge Fragrance Cartridge Precautions Programming the Appliance Using the Online SD Card Programming Tool Chapter 2: About AQ1570 Setting Scent Intensity Scent Control Chapter 3: Unpacking Chapter 7: USER MAINTENANCE Chapter 4: MOVING AND STORAGE...
  • Page 3: Chapter 1: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS Appliance Precautions WARNING – When using electric products, basic precautions should always be followed, including the following: • Read all the instructions before using the product. • Children should be supervised not to play with the appliance. •...
  • Page 4: Fragrance Cartridge Precautions

    Fragrance Cartridge Precautions • Use only AirQ by Prolitec fragrance cartridges. • Read the Consumer Product Safety Information Sheet and the Material Safety Data Sheet provided with each shipment of Cartridges. Ensure that these information sheets are available for review by employees.
  • Page 5: Chapter 2: About Aq1570

    About AQ1570 Welcome to a whole new world of air treatment from Prolitec, the technology leader in air care with scent. The AQ1570 is the most advanced commercial air-treatment system on the market today. It is the world’s first fully adjustable commercial air-treatment system engineered to serve indoor spaces.
  • Page 6 This user guide is easy to read. It is also important to read. AQ1570 is a high-performance appliance that, installed and used correctly, will meet the most demanding requirements. Table 1. Prolitec AirQ Technology vs. Aerosol Spray Can Technology Parameter...
  • Page 7 Unpacking Remove the AQ1570 Central Control Unit (CCU) from the container. The following items should be included: 1. AQ1570 CCU 2. Key 3. Mount Kit Remove the AQ1570 cartridge head(s) from the container(s). The following items should be included: 1. Cartridge Enclosure 2.
  • Page 8: Chapter 4: Moving And Storage Instructions

    MOVING AND STORAGE INSTRUCTIONS AQ1570 Central Control Unit (CCU) 1. Unplug the appliance. 2. Disconnect the airline tubing. 3. Unscrew and remove the long round-head screws in the upper and lower corners. 4. Remove the appliance from the wall. 5. Store at -4° F (-20°C) to 158° F (70°C), 5% to 95% humidity. AQ1570 cartridge head 1.
  • Page 9: Chapter 5: Installation

    Installation General Location The AQ1570 CCU is designed for permanent installation on wall surfaces near a 100-240V outlet. The AQ1570 cartridge head is designed for permanent installation on a wall surface. Service Area The service area range of each AQ1570 cartridge head is from 1,800-150,000 cubic feet (51-4245 cubic meters).
  • Page 10: Estimating Cartridge Life

    Estimating Cartridge Life Estimating how long a cartridge will last and the number of days between services is critical to performing an installation that can be serviced efficiently. This includes determining the number of AQ1570 cartridge heads needed for a space. Please refer to AirQ’s ‘S3 (Sizing, Service & Success) Tool,’...
  • Page 11: Appliance Location

    AQ1570 can use, rather than fight, the natural air currents in a room. 2. Air currents in a room are determined by using a SMOKE TEST KIT available from Prolitec or any source of smoke or vapor, such as a candle or match.
  • Page 12: Wall Mounting Aq1570

    Wall-Mounting AQ1570 Installation Kits One mounting kit is provided for each enclosure, and one plume kit is provided for each cartridge enclosure. SUB1400MOUNT contains the following: Four (4) drywall anchors for mounting in drywall Four (4) lead anchors for mounting in concrete Four (4) screws and four (4) washers for mounting in drywall and concrete Four (4) #10 self-tapping sheet metal screws for mounting in sheet metal KIT2500PLUME contains the following:...
  • Page 13: Ccu Installation

    CCU Installation 1. Place the CCU enclosure onto the desired location on the wall and ensure that it is level. 2. Fasten the CCU to the wall using the appropriate screws for the wall material. 3. Connect the power cord to a nearby outlet. Cartridge Unit Installation 1.
  • Page 14: Installing An Additional Module

    Installing an Additional Module To install an additional module in the CCU: Connect one wire harness to the two inputs (one red and one white) on the back of the circuit board of the new module, as shown. Place the connected module over the next four standoffs and use four screws to secure it in place.
  • Page 15 Push to connect the airline stem fitting to the bulkhead. AQ1570 Chapter 5 Installation...
  • Page 16: Chapter 6: Operating Instructions

    OPERATING INSTRUCTIONS Features and Controls Replaceable Battery Reset and Top Module Programming DC Jack Airline Fittings User Interface Second Module Connections for Add-On Modules Cartridge Unit Plume Kit assembled with Injector Locking Air Stem Tubing and Hose Airline Fittings Custom 2500mLCartridge AQ1570 Chapter 6...
  • Page 17: Setting Up The Cartridge

    Setting Up the Cartridge 1. Use the key to unlock and open the door of the cartridge head. 2. Prepare the cartridge. • Remove the big plug from the air-stem port (A) on the back side of the cartridge. • Remove the black screw cap from the top outlet port (B) of the cartridge.
  • Page 18: Programming The Appliance

    Programming the Appliance Unlock and open the door of the CCU. Turn on the power by pressing on the control panel. Set the Clock. • Press to cycle through the modes to the options mode. The day of the week will blink. •...
  • Page 19: Using The Online Sd Card Programming Tool

    • Press to set the intensity and the day of the week will blink. • Adjust the day of the week forward or backward using HINT: In addition to individual days, you can also set “all days,” “week days,” or “weekend days.” to set the day of the week.
  • Page 20 • Programs sets need to be saved. 3. Edit an existing program set using the edit button to the right of the program name. 4. Copy an existing program set using the copy button to the right of the program name. This can be especially useful for quickly duplicating a very similar set of programs.
  • Page 21 3. Press the reset button, and the five buttons will light in sequence from left to right. 4. The buttons will light alternately. for one second, and the display will show LOAD for about ten seconds. 5. Press and hold 6.
  • Page 22: Setting Scent Intensity

    Setting Scent Intensity Determine the approximate size of the room in cubic feet or cubic meters by multiplying length x width x ceiling height. Consult the Room-Size Table to give you a level (1 to 50) to set. THIS IS ONLY A STARTING POINT.
  • Page 23: Chapter 7: User Maintenance

    USER MAINTENANCE Cartridge Change When the reservoir is empty the cartridge needs to be changed. The change process is simple. Best practice is to wear gloves when manipulating the cartridge. 1. Unlock and open the doors of the CCU and cartridge enclosures. 2.
  • Page 24: Changing An Appliance

    Changing an Appliance Appliance malfunctions are not intended to be serviced in the field, however the inner module is field replacable. If there is no plume after following the procedure outlined above, contact Customer Care. General Care • AQ1570 is an electronic appliance. Treat it like a laptop. •...
  • Page 25 Air Filter and Check Valve (every year) AQ1570 is equipped with air filtration and a check valve system. The filter (PN 5251) collects fine dust. Replace every year. It is accessible behind the module housing. A layer of black dust on top of the filtering media is a sign that the filter should be replaced. To replace it, unscrew the 4 screws to remove the module and exchange the filter after pulling off the rubber tubing from both sides of the filter.
  • Page 26 Battery Replacement (approximately every two years) (Requires 3 Volt CR2032 Lithium Battery, PN 7115) Unlock and open the door to access the enclosure. Locate the CR2032 battery tray in the top module of the CCU. Pinch and pull the grip of the battery tray to remove the battery.
  • Page 27: Chapter 8: Applications

    There are four basic applications for AQ1570: ambient scenting, product marketing, odor control and aromatherapy. These applications are different in terms of their objectives, but they all employ the same combination of Prolitec’s proprietary air-treatment chemistry and AQ1570 computer-controlled delivery system.
  • Page 28: Product Marketing

    AQ1570 and Prolitec’s proprietary odor-remediation chemistry are capable of blocking the human ability to detect most malodors and replacing these odors with pleasant scents. Prolitec’s proprietary air-treatment chemistry and the accompanying computer-controlled delivery system are rapidly becoming the standard solution for difficult odor issues in several industry sectors.
  • Page 29: Aromatherapy And Performance Scenting

    The benefits include reduced errors in routine functions, increased employee sense of well being, higher morale, improved customer service and overall improved productivity. AQ1570™ and Prolitec aromatherapy chemistry can help make a workspace a more comfortable and appealing place to be. As examples of the positive effect of aromatherapy on the workplace, below are results of several relevant studies: •...
  • Page 30: Chapter 9: Frequently Asked Questions

    Frequently Asked Questions (FAQs) How does AQ1570 work? AQ1570 uses a patented technology to convert liquid fragrance compounds into tiny droplets less than 1/100th the diameter of a human hair. By comparison, an aerosol droplet is 100 times bigger and 1,000,000 times heavier. AQ1570 droplets present 100 times more surface area to the air being treated, which means much less fragrance is used to create the scent effect.
  • Page 31 How does AQ1570 differ from aerosol room fresheners? The more expensive aerosols can produce a very pleasant scent, but only for a few minutes and in very high concentrations just in the area they were sprayed. AQ1570 is what is known as a “continuous action”...
  • Page 32: Chapter 10: Specifications

    85% or less Liquid Capacity 2500mL cartridges Service Area Up to 150,000 cu. ft. (4245 m ) served per cartridge head Prolitec, Incorporated 1235 W. Canal Street Milwaukee, WI 53223 1-866-387-4333 www.prolitec.com All contents © 2019 Prolitec, Inc. AQ1570 Chapter 10 Specifications...

Table of Contents